Sale!

SIEMENS 3UF7320-1AB00-0 Failsafe Digital Module

Brand:Siemens

Model number:3UF7320-1AB00-0

Colour:new                                    Warranty: 12 months

Lead Time:3-day working day   Country of origin: USA

Price: Please contact us         Product weight:0.3kg

Category: SKU: 3UF7320-1AB00-0 Brand: ,

Description

SIEMENS 3UF7320-1AB00-0 Failsafe Digital Module

The Siemens 3UF7320-1AB00-0 is a DM-F Local fail-safe digital expansion module for the SIMOCODE pro motor management system. It lets you add hardwired safety shutdowns—like emergency stop buttons and safety guard switches—directly into your motor starter assembly.

 

Product Overview

The Siemens 3UF7320-1AB00-0 connects to a SIMOCODE pro V or SIMOCODE pro S basic unit to handle local safety functions independently of the main PLC. Instead of relying on network safety messages, it processes physical safety sensor signals directly on the module and trips its internal relay enabling circuits to cut power to the motor contactors.

 

Technical Specifications

  • Model & Series: 3UF7320-1AB00-0 (SIRIUS SIMOCODE pro DM-F Local)
  • Control Supply Voltage: 24 V DC
  • Safety Ratings: Up to SIL 3 (IEC 61508 / IEC 62061) and Performance Level e (PL e) (ISO 13849-1)
  • Relay Outputs: 2 fail-safe relay enabling circuits (2 NO contacts) for safe motor shutdown, plus 2 standard relay outputs for status/signaling
  • Control Inputs: Dedicated terminals for dual-channel sensor circuits, start signal, cascading input, and contactor feedback loop
  • Configuration Method: Front-panel DIP switches (sets sensor type, cross-circuit detection, and manual vs. automatic start)
  • Insulation & Surge Rating: 300 V rated insulation voltage; 4,000 V impulse withstand voltage
  • Operating Temperature: -25 °C to +60 °C
  • Weight: Approx. 0.36 kg

 

Key Advantages

  • High Safety Integrity: Meets SIL 3 and PL e standards, making it suitable for high-risk machinery without needing a separate safety relay.
  • Tool-Free Safety Setup: You set the safety logic directly using physical DIP switches on the module, so you don’t need special safety programming software.
  • Direct Hardware Shutdown: Cuts motor power immediately via local sensor wiring, keeping safety stops fast even if fieldbus communication drops.
  • Compact Cabinet Footprint: Replaces standalone external safety relays by snapping directly into the SIMOCODE pro system bus.

 

Important Usage & Installation Precautions

  • Verify Control Voltage: This exact part number (-1AB00-0) requires a 24 V DC supply. If your control cabinet uses 110–240 V AC/DC, you must use the 3UF7320-1AU00-0 variant instead.
  • DIP Switch Lock-In: Set all DIP switches before powering on the module, and make sure the protective cover is closed. Changing switch positions while powered triggers a safety fault that requires a power cycle.
  • Feedback Circuit Wiring: Always wire the normally closed (NC) mirror contacts of your main power contactors into the module’s feedback circuit so it can detect welded contacts.
  • Cross-Circuit Detection Limits: If you disable cross-circuit detection via the DIP switches (for example, when using OSSD electronic safety sensors), you must use shielded cables or separate routing to maintain SIL 3 / PL e compliance.
  • System Bus Connection: Connect the module to the SIMOCODE pro basic unit using the official system connecting cable before applying power.

 

Applications

  • Emergency Stop (E-Stop) Circuits: Monitors dual-channel E-stop pushbuttons on conveyors, mixers, and production lines.
  • Safety Guard & Door Interlocks: Shuts down motors immediately when operators open protective gates or light curtains trip.
  • Motor Control Centers (MCCs): Integrates certified functional safety directly into withdrawable or fixed MCC starter drawers.
  • Process Industry Pumps & Fans: Provides local, fail-safe shutdowns in chemical, oil & gas, and water treatment plants where hardwired safety overrides are mandatory.

Verdict: Choose the Siemens 3UF7320-1AB00-0 if you already use SIMOCODE pro motor controllers on a 24 V DC control system and want built-in SIL 3 / PL e hardware safety without wiring an extra safety relay. Skip it if your safety stops are triggered over PROFIsafe network telegrams rather than local wiring—in that case, look at the DM-F PROFIsafe (3UF7330) series instead.

Shipping Port: Xiamen, China

Payment: Bank of Chicago, Bank of Singapore

Express cooperation: fedex, DHL, UPS and your express account

Service: Professional Sales provides 24 hours /7 days online service

Please make an inquiry for more models:

SIEMENS 6DD1682-0CH0
SIEMENS 6DD1683-0CC0
SIEMENS 6DD1683-0CD0
SIEMENS 6DD2920-0AB0
SIEMENS 6DR2001-1
SIEMENS 6DS1200-8AB
SIEMENS 6DS1206-8AA
SIEMENS 6DS1212-8AB
SIEMENS 6DS1213-8AA
SIEMENS 6DS1311-8AE
SIEMENS 6DS1315-8AC
SIEMENS 6DS1322-8BA
SIEMENS 6DS1412-8DD
SIEMENS 6DS1601-8BA
SIEMENS 6DS1603-8BA
SIEMENS 6DS1618-8CA
SIEMENS 6DS1703-8AB
SIEMENS 6DS1717-8CC
SIEMENS 6DS1722-8BA
SIEMENS 6DS1723-8BA
SIEMENS 6DS1731-8DC
SIEMENS 6DS1731-8RR
SIEMENS 6DD1683-0BC5
SIEMENS 6DD1600-0AF0
SIEMENS 9AB4143-2EB23
SIEMENS 6DD1684-0CC1
SIEMENS 6DD1684-0CH0
SIEMENS 6DD1684-0DB2
SIEMENS 6DD1684-0DG1
SIEMENS 6DD1684-0DK0