Schneider QO116VSC10 Miniature Circuit Breaker
Product Overview
The Schneider Electric / Square D QO116VSC10 is a 1-pole, 16 A Miniature Circuit Breaker (MCB) from the Square D QOvs series. Designed for AC distribution systems, it provides reliable protection against electrical overloads and short circuits in commercial and industrial electrical distribution boards.
GSM Electrical Supplies+ 1
Featuring a C-curve tripping characteristic and a 10 kA short-circuit breaking capacity, it is specifically built to handle standard inductive loads and plug-on consumer units or distribution panels.
Kempston Controls
Part Number Breakdown & Technical Specifications
Catalog Number Decoding: QO116VSC10
- QOvs: Square D QOvs series plug-on / modular miniature circuit breaker.
GSM Electrical Supplies+ 1
- 1: 1-Pole (1 Protected Pole).
BPX
- 16: 16 Ampere rated continuous current (InI_nIn).
GSM Electrical Supplies
- V: Voltage rated design for 240/415 V AC distribution networks.
BPX
- C: C-curve magnetic tripping response (5×In5 \times I_n5×In to 10×In10 \times I_n10×In).
GSM Electrical Supplies+ 1
- 10: 10 kA short-circuit breaking capacity (IcnI_{cn}Icn).
Kempston Controls+ 1
Key Technical Specifications
| Parameter | Specification Details |
|---|---|
| Brand / Family | Schneider Electric / Square D (QOvs Series) |
| Product Model | QO116VSC10 |
| Product Type | Miniature Circuit Breaker (MCB) |
| Number of Poles | 1-Pole (1P / 1 Protected Pole) |
| Rated Current (In) | 16 A |
| Tripping Curve | C Curve (Magnetic trip: 5 to 10 ×In) |
| Rated Short-Circuit Breaking Capacity (Icn) | 10 kA at 240 V AC 50/60 Hz (IEC 60898-1) |
| Rated Operational Voltage (Ue) | 240 / 415 V AC (50/60 Hz) |
| Rated Insulation Voltage (Ui) | 500 V AC |
| Rated Impulse Withstand Voltage (Uimp) | 4 kV |
| Limitation Class | Class 3 |
| Mounting / Installation | Plug-on chassis / DIN rail option |
| Terminal Capacity | 1 mm² to 25 mm² (Rigid or Flexible copper wire) |
| Endurance | • Electrical: 4,000 cycles
• Mechanical: 20,000 cycles |
| Operating Temperature | -5 °C to +60 °C |
| Dimensions & Weight | 18.7 mm (W) × 81 mm (H) × 86.3 mm (D); ~104 g |
| Standards & IP Rating | EN/IEC 60898-1; IP20 (IP40 inside enclosure) |
Key Advantages
- High Short-Circuit Capacity (10 kA): Superior interrupting rating compared to standard 6 kA residential breakers, ensuring safety in demanding commercial and light industrial applications.
Kempston Controls
- Versatile C-Curve Characteristic: Prevents nuisance tripping from moderate inrush currents caused by small electric motors, fluorescent lighting banks, and transformers.
Kempston Controls
- Clear Status & Fault Trip Indication: Includes visual ON/OFF and trip status indication on the toggle/front face for rapid identification during troubleshooting.
GSM Electrical Supplies
- Fast and Secure Plug-On Installation: Plug-on chassis connection saves installation time and minimizes wiring connection points inside the distribution board.
GSM Electrical Supplies
- Robust Electrical Endurance: Built for long service life with up to 20,000 mechanical operations and 4,000 electrical operations under full load.
GSM Electrical Supplies+ 1
Important Usage & Installation Precautions
- Current Rating & Cable Matching: Ensure the 16 A rating matches the current-carrying capacity of the downstream wiring (typically minimum 2.5 mm22.5 mm^22.5 mm2 copper conductors) to ensure proper protection.
Kempston Controls
- Inrush Current Verification: C-curve breakers trip magnetically between 5 to 10 times the rated current (80 A80 A80 A to 160 A160 A160 A for a 16 A breaker). For loads with extremely high starting currents (e.g., large transformers), verify if a D-curve breaker is required instead.
Kempston Controls
- Terminal Tightening Torque: Maintain proper connection torque (recommended 2 N·m) on the bottom tunnel terminals to prevent loose wire terminations and localized terminal overheating.
Kempston Controls
- Enclosure Protection: The breaker itself is rated IP20. It must be installed inside a suitable distribution board or enclosure (IP40 or higher) to guard against dust, moisture, and accidental direct contact.
GSM Electrical Supplies+ 2
- Isolation Safety: Always switch off and isolate the main upstream feed before inserting or removing the plug-on breaker from the busbar assembly.
Applications
- Commercial Lighting Circuits: Suitable for controlling and protecting LED or fluorescent lighting networks with modest inrush current spikes.
- Small AC Motor Loads: Protection of fractional horsepower motors, exhaust fans, small pumps, and HVAC blowers.
- General Power Outlets: Protection of 16 A sub-circuits powering office equipment, shop tools, and general-purpose appliances.
GSM Electrical Supplies
- Commercial & Industrial Distribution Panels: Standard single-phase branch protection circuit breaker inside Square D / Schneider QO-compatible load centers and sub-panels.
Shipping Port: Xiamen, China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Please make an inquiry for more models:
| SCHNEIDER | 140CPU43412AC |
| SCHNEIDER | 140CPU43412U |
| SCHNEIDER | 140CPU43412UC |
| SCHNEIDER | 140CPU53414BC |
| SCHNEIDER | 140CPU65260C |
| SCHNEIDER | 140CPU65160C |
| SCHNEIDER | 140CHS11000C |
| SCHNEIDER | 140CHS21000C |
| SCHNEIDER | BMXDDI1602 |
| SCHNEIDER | BMXDDO1602 |
| SCHNEIDER | BMXAMI0810 |
| SCHNEIDER | BMXAMO0802 |
| SCHNEIDER | BMH2052P11A2A |
| SCHNEIDER | BMXDAO1605 |
| SCHNEIDER | BMXCPS3020 |
| SCHNEIDER | BMXDDO6402K |
| SCHNEIDER | BMXP342020H |
| SCHNEIDER | BMXEHC0800 |
| SCHNEIDER | BMXAMO0410 |
| SCHNEIDER | BMXXBP1200 |
| SCHNEIDER | 140CRA21120 |
| SCHNEIDER | 140ERT85420 |
| SCHNEIDER | 140N0E77100 |
| SCHNEIDER | 140NOC78000 |
| SCHNEIDER | 140NRP95400 |
| SCHNEIDER | 140SDI95300S |
| SCHNEIDER | 140SDO95300S |
| SCHNEIDER | TSXP57303AM |
| SCHNEIDER | 416NHM30032A |
| SCHNEIDER | 416NHM30030A |