Sale!

Schneider BMEP582040S CPU Module

Brand: Schneider

Model number: BMEP582040S

Colour:new                                    Warranty: 12 months

Lead Time:3-day working day   Country of origin: France

Price: Please contact us         Product weight:0.5kg

Category: SKU: BMEP582040S Brand:

Description

Schneider BMEP582040S CPU Module

The Schneider Electric BMEP582040S is a high-performance, safety-certified Programmable Automation Controller (PAC) from the Modicon M580 family. It is a dual-core processor designed specifically for functional safety applications, combining standard control and safety functions into a single, unified Ethernet-based architecture.

 

Product Detailed Description

The BMEP582040S is the heart of the Modicon M580 Safety system. It is a SIL3 (Safety Integrity Level 3) certified processor that allows industrial plants to run both standard automation tasks and safety-critical operations (such as emergency shutdowns or burner management) within the same controller chassis and software environment (EcoStruxure Control Expert). It utilizes native Ethernet communications to provide high-speed data exchange and cybersecurity features.

 

Technical Parameters

Feature / Parameter Specification
Product Series Modicon M580 Safety
Processor Type Safety Processor (Dual-Core: 1 Core for Standard, 1 Core for Safety)
Safety Certification SIL 3 (IEC 61508) / Category 4, PL e (ISO 13849-1)
Memory Capacity 8 MB (Standard application) + 4 MB (Safety application)
Built-in Communication Ports 1 x Ethernet (Service port), 2 x Ethernet (Device Network)
Max Number of I/O Up to 2048 discrete / 512 analog I/O channels
Cybersecurity Achilles Level 2 certification, encrypted firmware, port disabling
Current Consumption 270 mA at 24 V DC / 1200 mA at 3.3 V DC
Operating Temperature 0°C to +60°C (32°F to 140°F)

 

Product Advantages

  • Co-existence of Safety & Standard: Eliminates the need for separate safety PLCs. Standard and safety logic run on the same processor, reducing hardware footprint, wiring, and engineering costs.
  • Native Ethernet Backplane: Uses standard Ethernet for communication across the chassis backplane (X-Bus and Ethernet combined), ensuring massive data throughput and seamless connectivity.
  • High Cyber Resiliency: Equipped with advanced cybersecurity features natively embedded in the hardware, protecting the safety loop from unauthorized network interference or cyber-attacks.
  • Unified Software Environment: Programming, commissioning, and diagnostics for both standard and safety logic are managed within EcoStruxure Control Expert, simplifying team training and project development.
  • Hot-Swap Capability: Supports the replacement of standard or safety I/O modules while the system is powered and running, maximizing plant uptime.

 

Important Considerations & Precautions

  • Safety Lockout: Once the safety program is validated and locked, any modifications require strict adherence to functional safety management procedures and a security password.
  • Power Supply Requirements: Safety architectures require highly reliable, clean power. It is highly recommended to use dual-redundant power supplies (such as the BMXCPS4002S) specified for the M580 Safety range.
  • Module Compatibility: When building the rack, ensure that only safety-certified modules (identified by their distinct red casing or “S” suffix) are used for the safety-critical loops.
  • Firmware Matching: The processor firmware version must precisely match the library and hardware catalog versions in your programming software to maintain SIL3 compliance.

 

Product Applications

The BMEP582040S is ideal for industries requiring rigorous risk reduction and high availability:

  • Oil & Gas / Petrochemical: Emergency Shutdown Systems (ESD), Fire and Gas (F&G) monitoring, and burner management.
  • Chemical Processing: Monitoring critical reactions, managing pressure relief loops, and safeguarding toxic material containment.
  • Mining & Materials Handling: Protecting high-power conveyors, underground ventilation systems, and hoists where human safety is at risk.
  • Power Generation: Boiler protection systems, turbine trip mechanisms, and cooling tower safety controls.
  • Water & Wastewater: Safety overrides on high-pressure pumping stations and chemical dosing lines.

Shipping Port: Xiamen, China

Payment: Bank of Chicago, Bank of Singapore

Express cooperation: fedex, DHL, UPS and your express account

Service: Professional Sales provides 24 hours /7 days online service

Please make an inquiry for more models:

SCHNEIDER 140CPU43412AC
SCHNEIDER 140CPU43412U
SCHNEIDER 140CPU43412UC
SCHNEIDER 140CPU53414BC
SCHNEIDER 140CPU65260C
SCHNEIDER 140CPU65160C
SCHNEIDER 140CHS11000C
SCHNEIDER 140CHS21000C
SCHNEIDER BMXDDI1602
SCHNEIDER BMXDDO1602
SCHNEIDER BMXAMI0810
SCHNEIDER BMXAMO0802
SCHNEIDER BMH2052P11A2A
SCHNEIDER BMXDAO1605
SCHNEIDER BMXCPS3020
SCHNEIDER BMXDDO6402K
SCHNEIDER BMXP342020H
SCHNEIDER BMXEHC0800
SCHNEIDER BMXAMO0410
SCHNEIDER BMXXBP1200
SCHNEIDER 140CRA21120
SCHNEIDER 140ERT85420
SCHNEIDER 140N0E77100
SCHNEIDER 140NOC78000
SCHNEIDER 140NRP95400
SCHNEIDER 140SDI95300S
SCHNEIDER 140SDO95300S
SCHNEIDER TSXP57303AM
SCHNEIDER 416NHM30032A
SCHNEIDER 416NHM30030A