Description
Schneider A9F74325 Miniature Circuit Breaker
Product Overview
The Schneider Electric A9F74325 is a 3-Pole (3P), 25 A C-curve Miniature Circuit Breaker (MCB) from the flagship Acti9 iC60N series. It is engineered to provide overcurrent, short-circuit, and overload protection for three-phase low-voltage electrical distribution networks in commercial, industrial, and residential environments.
Equipped with Schneider’s proprietary VisiSafe and VisiTrip safety features, it ensures clear visual diagnostic feedback and maximum isolation security during maintenance.
Technical Specifications
| Parameter | Specification Details |
| Product Model / Reference | A9F74325 |
| Product Range | Acti9 iC60 / iC60N |
| Product Type | Miniature Circuit Breaker (MCB) |
| Number of Poles | 3P (3 Protected Poles) |
| Rated Current (I_n) | 25 A at 50 °C |
| Tripping Curve | C Curve (Magnetic trip: 8 \times I_n \pm 20\%) |
| Rated Operational Voltage (U_e) | 380…415 V AC 50/60 Hz (also rated \le 180 V DC) |
| Breaking Capacity (I_{cn} / I_{cu}) | • 6000 A I_{cn} @ 400 V AC (IEC/EN 60898-1)
• 10 kA I_{cu} @ 380…415 V AC (IEC/EN 60947-2) • 20 kA I_{cu} @ 220…240 V AC (IEC/EN 60947-2) |
| Rated Service Breaking Capacity (I_{cs}) | 7.5 kA (75% I_{cu}) @ 380…415 V AC |
| Rated Insulation Voltage (U_i) | 500 V AC 50/60 Hz (conforming to IEC/EN 60947-2) |
| Rated Impulse Withstand (U_{imp}) | 6 kV |
| Limitation Class | Class 3 (IEC/EN 60898-1) |
| Electrical / Mechanical Durability | 10,000 cycles (electrical) / 20,000 cycles (mechanical) |
| Mounting & Dimensions | 35 mm DIN rail mount; Width: 54 mm (6 modules of 9 mm); Height: 85 mm |
| IP Degree of Protection | IP20 (open device) / IP40 (inside modular enclosure) |
Key Advantages
- VisiSafe Isolation Security: Features a green indicator strip that guarantees physical contact separation across all 3 poles, ensuring safe downstream maintenance under IEC/EN 60947-2 isolation standards.
- VisiTrip Fault Identification: A red window indicator triggers instantly on an electrical fault, drastically reducing troubleshooting time by distinguishing trips from manual shutdowns.
- Class 2 Front Face Insulation: Provides maximum user protection against electric shock during manual switch operations.
- Top & Bottom Comb Busbar Compatibility: Supports quick and flexible power distribution via comb busbars from both top and bottom terminals.
- Wide Operating Range: Suitable for both AC networks and DC control applications up to 180 V DC.
Important Installation & Usage Precautions
- Tripping Curve Matching: The C-Curve trips magnetically at 5 to 10 times the rated current (8 \times I_n \pm 20\%). Ensure it matches inductive lighting and standard motor loads without nuisance tripping.
- Tightening Torque: Torque terminal screws to 2 N·m for proper connection integrity. Overtightening or undertightening can damage wire strands or cause overheating.
- Cable Cross-Section Limits: Use solid rigid wires up to 25 mm² or flexible crimped wires up to 16 mm² with a 14 mm stripping length.
- Environmental & Temperature Considerations: Rated for operating temperatures from -35 °C to +70 °C. Derating factors must be applied if the panel ambient temperature exceeds 50 °C.
- Power Isolation: Always de-energize the upstream panel and confirm zero voltage before inserting or removing wire connections.
Applications
- Commercial & Residential Panels: Three-phase main and sub-distribution circuit protection for office buildings, retail spaces, and high-rise apartments.
- Industrial Auxiliary Power: Circuit protection for small 3-phase motors, pumps, fans, and conveyor control circuits.
- HVAC Systems: Overcurrent protection for air handling units, small chillers, and compressor drives.
- Control Cabinet & OEM Machinery: DIN-rail mounted power protection inside automation cabinets and machine tools.
Shipping Port: Xiamen, China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Please make an inquiry for more models:
| SCHNEIDER | 140CPU43412AC |
| SCHNEIDER | 140CPU43412U |
| SCHNEIDER | 140CPU43412UC |
| SCHNEIDER | 140CPU53414BC |
| SCHNEIDER | 140CPU65260C |
| SCHNEIDER | 140CPU65160C |
| SCHNEIDER | 140CHS11000C |
| SCHNEIDER | 140CHS21000C |
| SCHNEIDER | BMXDDI1602 |
| SCHNEIDER | BMXDDO1602 |
| SCHNEIDER | BMXAMI0810 |
| SCHNEIDER | BMXAMO0802 |
| SCHNEIDER | BMH2052P11A2A |
| SCHNEIDER | BMXDAO1605 |
| SCHNEIDER | BMXCPS3020 |
| SCHNEIDER | BMXDDO6402K |
| SCHNEIDER | BMXP342020H |
| SCHNEIDER | BMXEHC0800 |
| SCHNEIDER | BMXAMO0410 |
| SCHNEIDER | BMXXBP1200 |
| SCHNEIDER | 140CRA21120 |
| SCHNEIDER | 140ERT85420 |
| SCHNEIDER | 140N0E77100 |
| SCHNEIDER | 140NOC78000 |
| SCHNEIDER | 140NRP95400 |
| SCHNEIDER | 140SDI95300S |
| SCHNEIDER | 140SDO95300S |
| SCHNEIDER | TSXP57303AM |
| SCHNEIDER | 416NHM30032A |