Product Overview

The Schneider Electric A9F44340 is a low-voltage 3-Pole 40A Miniature Circuit Breaker (MCB) belonging to the Acti9 iC60N series. Equipped with a C-curve thermal-magnetic tripping unit, it is engineered to protect electrical circuits against overloads and short circuits across commercial, residential, and industrial environments.

This model features Schneider Electric’s proprietary VisiSafe (guaranteed contact state visibility for safe isolation) and VisiTrip (red flag fault indicator) technologies.

 

Technical Specifications

Parameter Specification Details
Product Model / SKU A9F44340
Product Range Acti9 iC60N
Device Type Miniature Circuit Breaker (MCB)
Poles Description 3P (3 protected poles)
Rated Current (I_n) 40 A at 50 °C
Curve Code C Curve (magnetic trip 8 \times I_n \pm 20%)
Network Type / Frequency AC / DC (50/60 Hz)
Rated Operational Voltage (U_e) 380–415 V AC 50/60 Hz (also rated 12–440 V AC / \le 180 V DC)
Rated Breaking Capacity (I_{cu} / I_{cn}) • 10 kA I_{cu} @ 380–415 V AC (IEC/EN 60947-2)

• 6000 A I_{cn} @ 400/415 V AC (IEC/EN 60898-1)

• 20 kA I_{cu} @ 220–240 V AC (IEC/EN 60947-2)

Service Breaking Capacity (I_{cs}) 7.5 kA (75%) @ 380–415 V AC (IEC/EN 60947-2)
Rated Insulation Voltage (U_i) 500 V AC 50/60 Hz
Rated Impulse Withstand Voltage (U_{imp}) 6 kV
Control Type / Indicator Toggle handle; VisiTrip fault signaling & VisiSafe contact indication
Mounting & Width 35 mm DIN Rail clip-on; 54 mm width (6 pitches of 9 mm)
Wiring Connection Tunnel terminals: 1–35 mm² (rigid), 1–25 mm² (flexible)
Tightening Torque 3.5 N·m (Top or Bottom)
IP Degree of Protection IP20 (IP40 inside modular enclosure)
Endurance & Lifetime Electrical: 10,000 cycles | Mechanical: 20,000 cycles
Operating Temperature -35 °C to +70 °C

 

Key Advantages

  • VisiSafe Technology: Features a green strip that guarantees physical opening of the main contacts, ensuring complete safety during downstream maintenance in compliance with industrial isolation standards (IEC/EN 60947-2).
  • VisiTrip Fault Indicator: Displays a visible red indicator on the front panel upon an electrical fault trip, dramatically speeding up troubleshooting and reducing machine downtime.
  • Class 3 Energy Limitation: High current-limiting performance (Class 3 according to EN/IEC 60898-1) reduces electrical stress on downstream cables and equipment.
  • Fast Closing Mechanism: The closing speed is independent of manual toggle operation, extending electrical contact life and increasing durability.
  • Modular Add-On Expansion: Fully compatible with Vigi iC60 residual current devices (RCD blocks), auxiliary switches (OF/SD), shunt trips (iMX), and undervoltage releases (iMN).

 

Important Usage & Installation Precautions

  • De-Energize Before Wiring: Always isolate upstream power supplies before mounting, connecting, or adjusting conductors on the circuit breaker.
  • Torque Verification: Tighten the terminal screws to the specified 3.5 N·m torque. Loose connections cause excessive resistive heating and thermal tripping.
  • Conductor Sizing: Use copper cables sized correctly for a 40 A continuous rating (up to 35 mm² rigid or 25 mm² flexible wire). Strip conductors to exactly 14 mm.
  • Ambient Temperature Derating: The rated current (I_n = 40 A) is calibrated at 50 °C. If installed in high ambient temperature panels (>50 °C), apply temperature derating factors per Schneider Electric guidelines.
  • Enclosure Rating: The device itself is rated IP20. For outdoor or harsh industrial environments, it must be installed inside an enclosure rated IP54 or higher.

 

Primary Applications

  • 3-Phase Motor & Power Circuits: Distribution board protection for 3-phase machinery, HVAC chillers, compressors, and pump motors requiring a C-curve trip profile.
  • Commercial & Industrial Feeder Lines: Main or sub-feeder protection inside distribution panelboards, sub-distribution boards, and commercial switchboards.
  • Inductive Load Circuits: General power sub-circuits feeding fluorescent lighting arrays, transformers, and industrial power supplies where moderate inrush currents occur.

Shipping Port: Xiamen, China

Payment: Bank of Chicago, Bank of Singapore

Express cooperation: fedex, DHL, UPS and your express account

Service: Professional Sales provides 24 hours /7 days online service

Please make an inquiry for more models:

SCHNEIDER 140CPU43412AC
SCHNEIDER 140CPU43412U
SCHNEIDER 140CPU43412UC
SCHNEIDER 140CPU53414BC
SCHNEIDER 140CPU65260C
SCHNEIDER 140CPU65160C
SCHNEIDER 140CHS11000C
SCHNEIDER 140CHS21000C
SCHNEIDER BMXDDI1602
SCHNEIDER BMXDDO1602
SCHNEIDER BMXAMI0810
SCHNEIDER BMXAMO0802
SCHNEIDER BMH2052P11A2A
SCHNEIDER BMXDAO1605
SCHNEIDER BMXCPS3020
SCHNEIDER BMXDDO6402K
SCHNEIDER BMXP342020H
SCHNEIDER BMXEHC0800
SCHNEIDER BMXAMO0410
SCHNEIDER BMXXBP1200
SCHNEIDER 140CRA21120
SCHNEIDER 140ERT85420
SCHNEIDER 140N0E77100
SCHNEIDER 140NOC78000
SCHNEIDER 140NRP95400
SCHNEIDER 140SDI95300S
SCHNEIDER 140SDO95300S
SCHNEIDER TSXP57303AM
SCHNEIDER 416NHM30032A
SCHNEIDER 416NHM30030A