SCHNEIDER 140CPS22400 Redundant Power Supply Module
The Schneider Electric 140CPS22400 is a high-performance power supply module belonging to the Modicon Quantum automation platform. It is specifically designed to provide reliable DC power to the backplane, ensuring that all connected I/O modules and processors function correctly.
## Product Overview
The 140CPS22400 is a redundant-capable AC power supply. Its primary role is to convert a wide range of AC input voltages into the stabilized DC power required by the Quantum rack’s internal bus.
## Technical Parameters
| Feature | Specification |
| Product Compatibility | Modicon Quantum PLC platform |
| Input Voltage | 115 V to 230 V AC (Nominal) |
| Input Voltage Range | 93 V to 264 V AC |
| Network Frequency | 47 to 63 Hz |
| Output Current | 8 A (Secondary DC) |
| Power Consumption | 130 VA |
| Redundancy Support | Yes (Redundant capability) |
| Protection Type | Internal fuse (not user-serviceable) |
| Status Indicators | LED (Green for Power OK) |
## Product Advantages
-
Redundancy for Uptime: When used in a redundant configuration (two power supplies in one rack), the system can continue operating even if one unit fails, significantly reducing downtime.
-
Wide Voltage Range: Its ability to handle 115/230V AC makes it versatile for international electrical standards without needing manual switches.
-
High Power Density: Delivering 8 Amps of current allows it to support large, complex racks filled with high-density I/O modules.
-
Robust Build: Designed for industrial environments, it features high resistance to electromagnetic interference (EMI) and vibration.
## Important Precautions
Note on Safety: Always ensure the input power is disconnected before installing or removing the module to prevent electrical shock or damage to the backplane.
-
Heat Dissipation: Ensure the PLC cabinet has adequate ventilation. High-current power supplies generate heat; overcrowding can lead to thermal shutdown.
-
Redundancy Mapping: If using redundancy, ensure both power supplies are connected to different power sources if possible to maximize fault tolerance.
-
Fuse Maintenance: The internal fuse is permanent. If it blows, the unit usually requires professional repair or replacement rather than a simple fuse swap.
-
Grounding: Proper earthing of the Quantum rack is mandatory to protect the module from surges.
## Product Applications
The 140CPS22400 is typically found in mission-critical industrial sectors where system failure is not an option:
-
Oil & Gas: Controlling offshore platforms and refinery processes.
-
Power Generation: Managing turbine controls and substation automation.
-
Water Treatment: Large-scale filtration and distribution systems.
-
Manufacturing: High-speed assembly lines and automotive manufacturing where continuous operation is required.
Shipping Port: Xiamen, China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Please make an inquiry for more models:
| SCHNEIDER | 140CPU43412AC |
| SCHNEIDER | 140CPU43412U |
| SCHNEIDER | 140CPU43412UC |
| SCHNEIDER | 140CPU53414BC |
| SCHNEIDER | 140CPU65260C |
| SCHNEIDER | 140CPU65160C |
| SCHNEIDER | 140CHS11000C |
| SCHNEIDER | 140CHS21000C |
| SCHNEIDER | BMXDDI1602 |
| SCHNEIDER | BMXDDO1602 |
| SCHNEIDER | BMXAMI0810 |
| SCHNEIDER | BMXAMO0802 |
| SCHNEIDER | BMH2052P11A2A |
| SCHNEIDER | BMXDAO1605 |
| SCHNEIDER | BMXCPS3020 |
| SCHNEIDER | BMXDDO6402K |
| SCHNEIDER | BMXP342020H |
| SCHNEIDER | BMXEHC0800 |
| SCHNEIDER | BMXAMO0410 |
| SCHNEIDER | BMXXBP1200 |
| SCHNEIDER | 140CRA21120 |
| SCHNEIDER | 140ERT85420 |
| SCHNEIDER | 140N0E77100 |
| SCHNEIDER | 140NOC78000 |
| SCHNEIDER | 140NRP95400 |
| SCHNEIDER | 140SDI95300S |
| SCHNEIDER | 140SDO95300S |
| SCHNEIDER | TSXP57303AM |
| SCHNEIDER | 416NHM30032A |
| SCHNEIDER | 416NHM30030A |