Description
Pilz PZE 9 24VDC 8N/O 1N/C Safety relay
Product Dimensions:
The Pilz PZE 9 24VDC 8 N/O 1 N/C (Part Number 774150) is a specific configuration of a safety relay expansion module from the PNOZ X series. Its primary function is to increase the number of available safety contacts for a primary safety-related control component (like a safety relay, safety light curtain, or safety controller).
Key Features
-
Function: Contact expansion and amplification in connection with safety-related control components.
-
Safety Category: The device itself is an expansion block, and its safety level is dependent on the base unit it is connected to.
-
Inputs: Supports 1-channel or 2-channel wiring, with or without the capability to detect shorts across contacts in the input circuit.
-
Housing: Compact, rail-mountable unit.
📋 Product Specifications (Technical Data)
| Specification | Detail |
| Product ID | 774150 |
| Product Series | PNOZ X (Safety Relays) |
| Function | Contact Expansion/Amplification |
| Supply Voltage (UB) | 24 V DC |
| Power Consumption | 3.5 W (DC) |
| Inputs (Control Inputs) | 2 (Can be wired as 1 or 2-channel) |
| Outputs (Safety Contacts) | 8 N/O (Normally Open) Safety Contacts |
| Outputs (Auxiliary Contact) | 1 N/C (Normally Closed) Auxiliary Contact |
| Max. Current per Contact (AC1/DC1) | 8 A |
| Max. Current per Contact (AC15/DC13) | AC15: 5 A @ 230 V, DC13: 5 A @ 24 V |
| Connection Terminal | Screw Terminal (Fixed) |
| Dimensions (H x W x D) | 87 mm x 90 mm x 121 mm |
| Mounting | DIN rail |
| Ambient Temperature | -10 °C to 55 °C |
| Approvals | CCC, CE, UKCA, cULus Listed, TÜV, EAC |
✅ Product Advantages (Benefits)
-
High Contact Capacity: The primary advantage is the expansion of safety outputs. With 8 N/O safety contacts, it can safely control a large number of downstream devices (e.g., contactors, valves) from a single base safety function.
-
System Integration: Designed to work seamlessly with various Pilz safety base units (like PNOZ X, PNOZsigma, or safety controllers) via the feedback loop.
-
Safety Reliability: As a component of a safety circuit, it is built to the high standards required for safety-related applications, ensuring reliable switching of safety loads.
-
Short Detection: The input circuitry is capable of detecting short circuits across contacts, which is a crucial diagnostic feature for maintaining safety integrity.
-
Versatile Input Wiring: Offers flexibility with both 1-channel and 2-channel input configurations to suit different safety requirement levels.
⚠️ Important Considerations (Notes)
-
Installation/Wiring: Must be installed and wired strictly according to the official Pilz operating manual and relevant national/international safety standards (e.g., EN ISO 13849-1). Incorrect wiring can compromise the entire safety function.
-
Base Unit Required: This is an expansion module, meaning it must be connected to a primary safety control component (the base unit) that handles the core safety function (e.g., E-STOP monitoring, safety gate monitoring). It does not perform the primary monitoring function itself.
-
Feedback Loop: The base unit’s safety function must monitor the PZE 9’s contacts through a feedback loop (often monitored via the N/C auxiliary contact or a separate monitoring circuit) to ensure the contacts have opened correctly when required.
-
Load Rating: Always ensure that the current and voltage of the devices being switched (the load) do not exceed the maximum ratings specified for the PZE 9’s relay contacts.
⚙️ Product Applications
The Pilz PZE 9 expansion module is used in virtually all areas of industrial automation where a base safety function needs to switch multiple loads simultaneously.
-
Safety Gate Circuits: To distribute the safety signal from a safety gate monitor (base unit) to several contactors or motor control circuits in a complex machine cell.
-
E-STOP Circuits: When an Emergency Stop is triggered, the module provides enough contacts to simultaneously de-energize multiple drives, hydraulic valves, and other power sources.
-
Light Curtain/Scanner Integration: Used to amplify the safe output signal from a safety light curtain or laser scanner to control multiple downstream safety outputs.
-
Hydraulic/Pneumatic Control: To safely cut off the air or hydraulic supply to multiple moving parts or actuators after a safety command is initiated.
Shipping Port: Xiamen, China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Please make an inquiry for more models:
| PILZ | PMIV316WIFAG |
| pilz | 301112 |
| PINNACLE | MG-32-OF-20-220VAC |
| PINNACLE | MG-56-OF1-06-MO |
| PINNACLE | MGK-24-OF-AU |
| PINNACLE | TPG-60-3.0-35 |
| PIONEER | PM3398B-6-1-3-E |
| PIONEER MAGNETICS | PM3328B-6-1-3-E |
| PIONEER MAGNETICS | PM3398BP-6-1-3-E |
| PIONEER MAGNETICS | PM1253AL-6-3-Z03 |
| PIONEERMAGNETICS | PM3328B-6-1-3-E |
| PIONEERMAGNETICS | PM3398BP-6-1-3-E |
| PLC | 1769-L35CR |
| PLEIGER | PPC-IPC-S |
| PLEIGER | PPC-IPC-S |
| PLEIGER | PPC-IPC-S |
| PMA | TB45-112-00000-000 |
| PNEUMATIC | VDP24SDDD36 |
| PNEU-TURN | CPT-00568-A |
| POLYSPEDE | PRD2-200 |
| Polytec | CLV-1000 |
| PORTER | LB-366 NVL-003F |
| PORTER | LB-366 NVL-003F |
| Power-one | MAP55-1024 |
| PPT | 661-0326-C30 |
| PPT | 661-0342-T10 |
| Pringle | QA-B-1633-S |
| PRO | SC203-100A-002IR-010-01K-05 |
| PRO | SC203-100A-002IR-010-01K-05 |
| PRO | PS3710A-T42-1G-NO60 |