Description
Honeywell CPO-RS2 HVAC fan coil unit controller
Product Overview
The Honeywell CPO-RS2 (CentraLine Room Sensor 2) is a digital room sensor designed for climate and temperature monitoring within building automation and HVAC management systems. It communicates directly with compatible Honeywell/CentraLine room controllers (such as the CPO-RL series or EAGLE system controllers) over a dedicated bus, providing precise ambient temperature sensing and local user override capabilities.
Technical Specifications
| Parameter | Specification Details |
| Product Model | CPO-RS2 |
| Manufacturer | Honeywell / CentraLine |
| Product Category | Digital Room Sensor / Room Operating Panel |
| Measured Parameter | Ambient Air Temperature |
| Temperature Sensing Range | 0 °C to +50 °C (32 °F to 122 °F) |
| Measurement Accuracy | ±0.2 K @ 25 °C |
| Communication Interface | Dedicated Field Bus / Sylk™ Bus (2-wire polarity-independent) |
| Operating Voltage | Powered via communication bus (no local power supply required) |
| User Controls | Integrated setpoint adjustment wheel/buttons and occupancy bypass button |
| Display | Optional LCD screen showing current room temperature / setpoint offset |
| Housing Material | ABS plastic (Flame retardant, UL94-V0) |
| Protection Rating | IP30 |
| Operating Temperature | 0 °C to +50 °C (32 °F to 122 °F) |
| Storage Temperature | -20 °C to +70 °C (-4 °F to 158 °F) |
| Mounting Type | Direct wall mounting or standard conduit box installation |
Key Advantages
- Simple 2-Wire Installation: Uses a polarity-independent, 2-wire bus connection (Sylk™ bus technology), significantly simplifying field wiring and reducing installation costs.
- Bus-Powered: Operates directly on power supplied by the controller over the communication bus—no external power supply or batteries needed.
- Precise Local Control: Allows room occupants to easily adjust local temperature setpoints and trigger temporary occupancy override modes.
- Seamless Controller Integration: Native compatibility with Honeywell CentraLine BACnet controllers ensures instant auto-discovery and error-free telemetry integration.
- Clean Architectural Design: Features a modern, unobtrusive white housing suitable for high-end commercial office space, healthcare facilities, and educational environments.
Important Installation & Safety Precautions
- Avoid Thermal Distortions: Do not install the sensor near direct sunlight, drafting windows, exterior doors, or heat-generating devices (radiators, computers, printers).
- Proper Air Circulation: Mount the sensor on an interior wall approximately 1.5 meters (5 feet) above the finished floor level to ensure representative air temperature readings.
- Conduit Sealing: Seal the conduit opening behind the mounting plate to prevent cool or warm air draft inside wall cavities from affecting temperature measurement accuracy.
- Wiring Distance: Ensure the bus wiring length between the controller and the CPO-RS2 does not exceed recommended manufacturer limits for the specific cable gauge used (typically up to 100 meters with twisted-pair wiring).
- Electrostatic Discharge (ESD): Handle circuit board components with care during mounting to prevent static discharge damage.
Applications
- Commercial Office Buildings: Individual zone temperature monitoring and occupant setpoint adjustment in variable air volume (VAV) or fan coil unit (FCU) zones.
- Educational Facilities: Room climate control for classrooms, lecture halls, and administrative offices.
- Hotels & Hospitality: Guest room temperature control panels linked to central building management systems (BMS).
- Healthcare & Labs: Environmental temperature monitoring in non-critical hospital rooms, clinics, and staff suites.
Shipping Port: Xiamen, China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Please make an inquiry for more models:
| Honeywell | 621-9938 30731823-001 |
| Honeywell | 82408458-002 8240846-001 |
| Honeywell | CC-PAIM01 51405046-175 |
| Honeywell | FSC10002/1/2 |
| Honeywell | FSC10014/H/F |
| Honeywell | FSC10101/2/1 |
| Honeywell | MC-TAMR03 51309218-175 |
| Honeywell | MC-TAMR04 51305907-175 |
| Honeywell | 0AH061 |
| Honeywell | 10014/F/F |
| Honeywell | 10024/I/I |
| Honeywell | 10105/2/1.10105/2/1 |
| Honeywell | 10201/2/1.10201/2/1 |
| Honeywell | 11CX12-D01 |
| Honeywell | 1TC-PPD011 |
| Honeywell | 281CX12 |
| Honeywell | 2MLR-DBSH |
| Honeywell | 330103-00-06-10-02-00 |
| Honeywell | 4000093-310 |
| Honeywell | 50MC-PAIH03 |
| Honeywell | 51201420-005 |
| Honeywell | 51204138-001 |
| Honeywell | 51204162 |
| Honeywell | 51303978 |
| Honeywell | 51303979-500 |
| Honeywell | 51304441 |
| Honeywell | 51304486-100 |
| Honeywell | 51304754-1 |
| Honeywell | 51305418-200 |
| Honeywell | 51305803-100 |