Description
HONEYWELL 900A16-0101 16-Channel High-Level Analog Input Module
Product Overview
The Honeywell 900A16-0101 is a high-density, 16-channel high-level analog input module engineered for the ControlEdge HC900 hybrid control and safety system.
It provides precise data acquisition for high-level process variables, accepting standard voltage (e.g., 0–5V, 0–10V, 1–5V) and current loop signals (e.g., 4–20mA, 0–20mA). With point-to-point solid-state galvanic isolation and fast A/D conversion, this module is designed for continuous, high-reliability operation in harsh industrial environments.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Manufacturer & Model | Honeywell 900A16-0101 |
| System Compatibility | Honeywell ControlEdge / HC900 Controller Racks |
| Number of Channels | 16 High-Level Analog Input Channels |
| Supported Signal Types | • Voltage: 0 to 5 V DC, 1 to 5 V DC, 0 to 10 V DC, ±10 V DC
• Current: 0 to 20 mA, 4 to 20 mA (requires precision 250 Ω resistor) |
| Input Impedance | > 1 MΩ (Voltage Inputs) | 250 Ω (Current Inputs) |
| A/D Resolution | ±15 bits (High Precision) |
| Module Scan / Update Rate | 100 ms module update time |
| Galvanic Isolation | • 400 V DC Point-to-Point (Solid-State Switching)
• 1000 V DC Channel-to-Logic Isolation |
| Accuracy & Stability | • Temp Effect: Max ±0.01% of full scale per °C
• Long-term stability: 0.1% / year |
| Noise Rejection | • Common Mode Rejection Ratio (CMRR): > 90 dB @ 120 V AC
• Series Mode Rejection Ratio (SMRR): > 31 dB |
| Internal Power Consumption | • 5 V DC Backplane: 75 mA max
• 24 V DC External Supply: 50 mA max |
| Environmental Protection | G3 level conformal coating (harsh chemical/corrosive protection) |
| Operating Temperature | 0 °C to +60 °C (32 °F to 140 °F) |
Key Advantages
- High Channel Density: Accommodates 16 analog input channels in a single 1.4-inch-wide module slot, maximizing rack space efficiency in switchboards and cabinets.
- Point-to-Point Isolation: Solid-state switching provides galvanic point-to-point isolation, preventing ground loops between process transmitters and protecting adjacent system hardware.
- G3 Conformal Coating: Standardized coating against corrosive atmospheres (such as airborne hydrogen sulfide and chlorine), making it ideal for harsh chemical or wastewater environments.
- Exceptional Accuracy & Stability: Features 15-bit A/D resolution with low temperature drift (±0.01%/°C), delivering precise measurements for critical loops.
- Flexible Termination Options: Works seamlessly with Honeywell DIN-rail mounted Remote Terminal Panels (RTPs) and pre-wired cable assemblies to cut wiring labor and field commissioning times.
Important Usage & Installation Precautions
- Current Shunt Resistor Requirement: When measuring current loop inputs (4–20 mA), ensure the corresponding 250 Ω precision shunt resistors are correctly installed across the input terminals as specified in the HC900 hardware manual.
- Field Wiring Routing: Use shielded twisted-pair cables for signal wiring. Route analog signal lines separately from high-voltage AC cables and motor drives to preserve the >90 dB common-mode noise rejection.
- Hot-Swapping Rules: Refer to system software guidelines before inserting or removing the module. Ensure the rack address keying and slot assignments match the HC900 Designer configuration.
- Terminal Grounding: Connect cable shields strictly to the designated chassis/earth ground bar at one end only to prevent ground loop noise from degrading analog readings.
- Environmental Enclosure: Install inside a minimum NEMA 12 / IP54 rated control panel to keep ambient operating temperatures within 0°C to 60°C and maintain non-condensing humidity levels (10% to 90%).
Applications
- Process Loop Monitoring: Ideal for centralizing measurements of temperature, pressure, flow rate, and liquid level transmitters across industrial processing plants.
- Furnaces, Kilns & Boilers: High-density feedback collection for multi-zone thermal profile tracking and combustion control.
- Chemical & Pharmaceutical Manufacturing: Real-time data logging and batch process monitoring in reactors, autoclaves, and drying units.
- Water & Wastewater Treatment: Continuous measurement of tank levels, flow rates, pump head pressures, and chemical feed dosages.
- Oil, Gas & Energy Systems: Pipeline pressure/flow telemetry, compressor station telemetry, and power generation monitoring.
Shipping Port: Xiamen, China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Please make an inquiry for more models:
| Honeywell | 621-9938 30731823-001 |
| Honeywell | 82408458-002 8240846-001 |
| Honeywell | CC-PAIM01 51405046-175 |
| Honeywell | FSC10002/1/2 |
| Honeywell | FSC10014/H/F |
| Honeywell | FSC10101/2/1 |
| Honeywell | MC-TAMR03 51309218-175 |
| Honeywell | MC-TAMR04 51305907-175 |
| Honeywell | 0AH061 |
| Honeywell | 10014/F/F |
| Honeywell | 10024/I/I |
| Honeywell | 10105/2/1.10105/2/1 |
| Honeywell | 10201/2/1.10201/2/1 |
| Honeywell | 11CX12-D01 |
| Honeywell | 1TC-PPD011 |
| Honeywell | 281CX12 |
| Honeywell | 2MLR-DBSH |
| Honeywell | 330103-00-06-10-02-00 |
| Honeywell | 4000093-310 |
| Honeywell | 50MC-PAIH03 |
| Honeywell | 51201420-005 |
| Honeywell | 51204138-001 |
| Honeywell | 51204162 |
| Honeywell | 51303978 |
| Honeywell | 51303979-500 |
| Honeywell | 51304441 |
| Honeywell | 51304486-100 |
| Honeywell | 51304754-1 |
| Honeywell | 51305418-200 |
| Honeywell | 51305803-100 |