Description
Honeywell 51204162-175 DIN-Rail/Mountable Temperature Transmitter Module
Product Dimensions:
Honeywell offers highly reliable DIN-Rail Mountable Temperature Transmitters designed for high-density installation within control cabinets. The most prominent modern series for this application is the SmartLine STT850 and STT750 DIN-rail variants, as well as the classic STT350 and STT250 modules adapted with DIN-rail clips.
Product Detailed Description
These modules are designed to convert low-level signals from temperature sensors—specifically RTDs (Resistance Temperature Detectors) and Thermocouples—into a highly stable, noise-immune 4–20 mA analog output (often superimposed with digital HART, DE, or Foundation Fieldbus protocol). By mounting these transmitters on a standard 35mm DIN rail inside a marshaling cabinet, industrial plants can centralize their temperature loops, simplify field wiring, and protect sensitive electronics from harsh process environments.
Typical Technical Parameters
The following parameters reflect the high-performance STT850 / STT750 DIN-rail specification standard.
| Parameter | Specification |
| Input Channels | Single or Dual Input (Supports differential/average measurement) |
| Sensor Inputs | RTDs (Pt100, Pt200, Pt500, Pt1000, Cu, Ni)
Thermocouples (Type B, E, J, K, N, R, S, T) Resistance (0–4000 Omega) / Millivolts (-20 to +100 mV) |
| Output Signal | 4–20 mA DC with HART 7, Honeywell DE, or Foundation Fieldbus |
| Digital Accuracy | Up to pm 0.10^circC for Pt100 RTD (Model specific) |
| Galvanic Isolation | 2000 V AC between input and output |
| Power Supply | 11 to 42 V DC (Loop-powered) |
| Housing Width | Compact profile (typically 22.5 mm or less) |
| Safety Certification | SIL 2/3 Certified (IEC 61508) |
Product Advantages
- Space-Saving Design: The slim DIN-rail form factor allows dozens of transmitters to be packed into a single control cabinet, significantly reducing floor space requirements.
- Dual-Input Capabilities: Advanced models support two independent temperature sensors. This enables sensor backup (automatic failover if one sensor breaks) or drift detection to warn operators if calibration is slipping.
- Universal Input Configuration: A single module can be programmed via HART or PC software to accept almost any sensor type, drastically reducing spare parts inventory.
- Galvanic Isolation: High input-to-output isolation protects upstream PLC/DCS analog cards from localized ground loops and electrical noise generated in the field.
Important Considerations & Precautions
- Cold Junction Compensation (CJC): When using thermocouples, ensure the module’s internal CJC sensor is stable. Avoid mounting the transmitter near heat-generating components (like power supplies or VFDs) inside the cabinet, as rapid ambient temperature fluctuations can cause measurement errors.
- Lead Wire Resistance: For RTD measurements, use 3-wire or 4-wire configurations over long distances to automatically compensate for the resistance of the copper lead wires.
- Power Supply Ripple: Ensure the 24V DC loop power is clean. Excessive AC ripple on the DC line can disrupt the digital HART communication overlay.
- Sensor Burnout Action: Configure the fail-safe mode (Upscale or Downscale) during commissioning so that the DCS knows exactly how to handle a broken sensor wire safely.
Product Applications
- Refining & Chemical Cabinets: Centralizing temperature data from distillation columns, reactors, and storage tanks into remote instrument enclosures.
- Power Plant Monitoring: Tracking steam, bearing, and exhaust temperatures where high-density channel counts are required near the turbine control systems.
- HVAC & Cleanrooms: Used in environmental monitoring systems for pharmaceutical facilities where strict temperature tracking is mandatory for compliance.
- Factory Automation / OEMs: Integration into standardized machinery control panels requiring precise thermal management.
Shipping Port: Xiamen, China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Please make an inquiry for more models:
| Honeywell | 621-9938 30731823-001 |
| Honeywell | 82408458-002 8240846-001 |
| Honeywell | CC-PAIM01 51405046-175 |
| Honeywell | FSC10002/1/2 |
| Honeywell | FSC10014/H/F |
| Honeywell | FSC10101/2/1 |
| Honeywell | MC-TAMR03 51309218-175 |
| Honeywell | MC-TAMR04 51305907-175 |
| Honeywell | 0AH061 |
| Honeywell | 10014/F/F |
| Honeywell | 10024/I/I |
| Honeywell | 10105/2/1.10105/2/1 |
| Honeywell | 10201/2/1.10201/2/1 |
| Honeywell | 11CX12-D01 |
| Honeywell | 1TC-PPD011 |
| Honeywell | 281CX12 |
| Honeywell | 2MLR-DBSH |
| Honeywell | 330103-00-06-10-02-00 |
| Honeywell | 4000093-310 |
| Honeywell | 50MC-PAIH03 |
| Honeywell | 51201420-005 |
| Honeywell | 51204138-001 |
| Honeywell | 51204162 |
| Honeywell | 51303978 |
| Honeywell | 51303979-500 |
| Honeywell | 51304441 |
| Honeywell | 51304486-100 |
| Honeywell | 51304754-1 |
| Honeywell | 51305418-200 |
| Honeywell | 51305803-100 |