Description
Honeywell 51202304-100 Differential Pressure Transmitter
Product Dimensions:
Honeywell offers industry-leading Differential Pressure (DP) Transmitters, primarily under the SmartLine® ST800 and ST700 series. These high-performance instruments are designed to measure the difference between two pressures and convert it into an electrical signal for process control and monitoring.
Product Detailed Description
Honeywell SmartLine DP Transmitters utilize advanced piezoresistive sensor technology. By combining differential pressure sensing with on-board static pressure and temperature compensation, these devices deliver exceptional accuracy and stability even under harsh operating conditions. They can be configured with various process connections, including traditional flanges, remote seals, or manifolds, to measure flow, liquid level, or filter degradation.
Typical Technical Parameters
Specifications below represent the premium SmartLine ST800 series.
| Parameter | Specification |
| Measuring Ranges | From 0…1 mbar up to 0…70 bar (depending on capsule) |
| Turndown Ratio | Up to 400:1 (highly configurable span) |
| Reference Accuracy | Up to pm 0.025% of calibrated span |
| Output Options | 4–20 mA DC, HART 7, Foundation Fieldbus, or DE Protocol |
| Stability | pm 0.01% of URL per year for up to 15 years |
| Static Pressure Rating | Standard 210 bar (Up to 420 bar high-pressure models) |
| Housing Material | Aluminum (Epoxy coated) or 316 Stainless Steel |
| Wetted Materials | 316L SS, Hastelloy C-276, Monel, or Tantalum |
| Safety Certification | SIL 2/3 certified as standard |
Product Advantages
- Modular Design: Electronics modules, alphanumeric displays, and terminal blocks can be replaced or upgraded in the field without affecting the transmitter’s calibration or breaking the process seal.
- Dual-Surface Diagnostics: Advanced diagnostic capabilities monitor both the sensor health and the process loop conditions, helping operators detect issues like plugged impulse lines.
- Integrate Architecture: Seamless integration with Honeywell Experion® PKS provides transmitter messaging, maintenance mode indications, and tamper alerts directly to the control room.
- Intuitive Display: Available with an advanced graphic LCD that supports multi-language displays, trend charts, and clear diagnostic messaging.
Important Considerations & Precautions
- Impulse Line Routing: For liquid or steam applications, mount the transmitter below the process taps and slope the impulse lines downward to prevent gas bubbles from trapping. For gas applications, mount the transmitter above the taps to allow condensate to drain back into the process.
- Static Pressure Over-loading: When commissioning the unit, open the stabilizing (equalizing) valve on the manifold first before opening the high and low-pressure block valves to prevent accidental over-pressurization on a single side of the sensor capsule.
- Material Selection: Ensure that the selected wetted materials (diaphragm and fill fluid) are compatible with the process medium to avoid hydrogen permeation or chemical corrosion.
- Seal Integrity: Regularly check the O-rings and process flange bolts for leaks, especially in high-temperature or thermal-cycling processes.
Product Applications
- Flow Measurement: Paired with primary flow elements like orifice plates, Venturi tubes, or Pitot tubes to calculate fluid, gas, or steam flow rates.
- Liquid Level Measurement: Measuring the hydrostatic head in pressurized or open vessels to determine tank level, density, or interface layers.
- Filter Monitoring: Measuring the pressure drop across industrial filters, strainers, or heat exchangers to trigger backwash sequences or maintenance alerts.
- Draft and Furnaces: Monitoring low-pressure draft conditions inside industrial boilers, kilns, and exhaust stacks.
Shipping Port: Xiamen, China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Please make an inquiry for more models:
| Honeywell | 621-9938 30731823-001 |
| Honeywell | 82408458-002 8240846-001 |
| Honeywell | CC-PAIM01 51405046-175 |
| Honeywell | FSC10002/1/2 |
| Honeywell | FSC10014/H/F |
| Honeywell | FSC10101/2/1 |
| Honeywell | MC-TAMR03 51309218-175 |
| Honeywell | MC-TAMR04 51305907-175 |
| Honeywell | 0AH061 |
| Honeywell | 10014/F/F |
| Honeywell | 10024/I/I |
| Honeywell | 10105/2/1.10105/2/1 |
| Honeywell | 10201/2/1.10201/2/1 |
| Honeywell | 11CX12-D01 |
| Honeywell | 1TC-PPD011 |
| Honeywell | 281CX12 |
| Honeywell | 2MLR-DBSH |
| Honeywell | 330103-00-06-10-02-00 |
| Honeywell | 4000093-310 |
| Honeywell | 50MC-PAIH03 |
| Honeywell | 51201420-005 |
| Honeywell | 51204138-001 |
| Honeywell | 51204162 |
| Honeywell | 51303978 |
| Honeywell | 51303979-500 |
| Honeywell | 51304441 |
| Honeywell | 51304486-100 |
| Honeywell | 51304754-1 |
| Honeywell | 51305418-200 |
| Honeywell | 51305803-100 |