Honeywell 14506788-004 Terminal Base for AI Module
Product Dimensions:
Honeywell offers high-reliability Terminal Bases—commonly referred to as I/O Termination Assemblies (IOTAs)—primarily within its flagship Experion® PKS Series C architecture. These components serve as the physical and electrical foundation for mounting Analog Input (AI) modules, such as the CC-PAIH02.
Product Detailed Description
The Terminal Base (IOTA) is a passive, rugged hardware assembly that mounts directly onto a DIN rail. It houses the physical screw or compression terminals for field wiring and features specialized edge connectors to accept the active I/O electronics module.
By separating the wiring interface from the electronics, Honeywell allows all field cables to be landed and commissioned before the sensitive AI cards are plugged in. These bases are available in both Non-Redundant (holding one AI module) and Redundant (holding two AI modules in a master/slave configuration) variations.
Typical Technical Parameters
Specifications below represent standard metrics for a typical Series C Redundant AI IOTA (e.g., CC-TAIH11 / CC-TAIH01).
| Parameter | Specification |
| Compatible Modules | CC-PAIH01, CC-PAIH02 (HART Analog Input) |
| Channel Capacity | 16 Channels |
| Wiring Connection | Screw-type or Compression-type terminals |
| Wire Size Range | 0.3 to 2.5 mm^2 (22 to 12 AWG) |
| Supply Voltage | 24 V DC (Redundant power distribution buses) |
| Fusing | Typically 1 fuse per channel or per module pair (depending on model) |
| Flammability Rating | UL 94 V-0 |
| Coating Option | Conformal coating available for Class G3 harsh environments |
Product Advantages
- True Hot-Swapping: Redundant terminal bases allow a failed Analog Input card to be pulled out and replaced while the process is live, without dropping loop power or interrupting the control signal.
- Separation of Labor: Field wiring can be routed, connected, and loop-tested by electricians during plant construction before the expensive control cards are even unboxed.
- Reduced Cabinet Footprint: The compact, vertical design of the Series C IOTA optimizes space within marshalling cabinets compared to traditional horizontal terminal blocks.
- Integrated Power Routing: Power distribution for 2-wire field transmitters is built directly into the IOTA circuitry, removing the need for external, bulky distribution fuse blocks.
Important Considerations & Precautions
- Torque Specifications: Always tighten terminal screws to the manufacturer-specified torque rating. Under-tightening causes loose connections and signal drift, while over-tightening can crack the carrier board.
- Fused Protection: When working with 4-wire (externally powered) transmitters, ensure the IOTA is configured correctly to prevent feeding external power backwards into the 24V DC internal bus.
- Creepage and Clearance: Maintain cleanliness inside the cabinet. Conductive dust or moisture buildup on the exposed surface of the IOTA can bridge channels and cause cross-talk or short circuits.
- Shield Grounding: Land the field instrument cable shields on the designated grounding bar attached to the IOTA carrier, rather than daisy-chaining them, to preserve signal integrity against electromagnetic interference (EMI).
Product Applications
Honeywell Terminal Bases are used across heavy processing industries where Experion distributed control systems (DCS) are deployed:
- Refining & Petrochemical: Houses AI modules monitoring critical critical loop pressures, safety temperatures, and custody-transfer flows.
- Offshore Oil Platforms: Used in tight control rooms where the compact vertical design saves vital structural space.
- Power Plants: Interfaces heavy-duty instrumentation monitoring boiler drums, steam turbines, and cooling systems.
- Chemical Batch Plants: Provides rapid maintenance capabilities where a control hardware failure could ruin an expensive product batch.
Shipping Port: Xiamen, China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Please make an inquiry for more models:
| Honeywell | 621-9938 30731823-001 |
| Honeywell | 82408458-002 8240846-001 |
| Honeywell | CC-PAIM01 51405046-175 |
| Honeywell | FSC10002/1/2 |
| Honeywell | FSC10014/H/F |
| Honeywell | FSC10101/2/1 |
| Honeywell | MC-TAMR03 51309218-175 |
| Honeywell | MC-TAMR04 51305907-175 |
| Honeywell | 0AH061 |
| Honeywell | 10014/F/F |
| Honeywell | 10024/I/I |
| Honeywell | 10105/2/1.10105/2/1 |
| Honeywell | 10201/2/1.10201/2/1 |
| Honeywell | 11CX12-D01 |
| Honeywell | 1TC-PPD011 |
| Honeywell | 281CX12 |
| Honeywell | 2MLR-DBSH |
| Honeywell | 330103-00-06-10-02-00 |
| Honeywell | 4000093-310 |
| Honeywell | 50MC-PAIH03 |
| Honeywell | 51201420-005 |
| Honeywell | 51204138-001 |
| Honeywell | 51204162 |
| Honeywell | 51303978 |
| Honeywell | 51303979-500 |
| Honeywell | 51304441 |
| Honeywell | 51304486-100 |
| Honeywell | 51304754-1 |
| Honeywell | 51305418-200 |
| Honeywell | 51305803-100 |