HONEYWELL 10018E1 Sensor
Product Dimensions:
The Honeywell 10018/E/1 is a high-density, safety-certified Digital Input Module belonging to the Safety Manager (and legacy FSC – Fault Tolerant Student Controller) system. It is designed to interface field-mounted dry contacts or proximity switches with the Safety Manager controller.
Product Detailed Description
The 10018/E/1 module features 16 input channels that are designed for use in safety-critical loops. The “E” designation indicates enhanced diagnostic capabilities, and the “1” typically refers to the hardware revision or a specific coating for environmental protection. This module is “fail-safe,” meaning it is designed to ensure that any internal hardware failure results in a predictable and safe state for the process.
Technical Parameters
| Parameter | Specification |
| Model Number | 10018/E/1 |
| Number of Channels | 16 (Digital) |
| Input Voltage | 24 V DC (nominal) |
| Input Current | Approx. 7 mA per channel at 24 V DC |
| “Off” State Voltage | < 5 V DC |
| “On” State Voltage | > 15 V DC |
| Power Dissipation | 1.8 W (all channels active) |
| Safety Integrity Level | SIL 3 (IEC 61508) |
| Module Width | 4 TE (standard rack width) |
| Status Indication | LED per channel + Module Status LED |
Product Advantages
- High Integrity (SIL 3): Specifically designed for high-risk industrial environments where human life and environmental protection are the highest priority.
- Comprehensive Diagnostics: The module continuously monitors its internal circuits and the status of the input channels, providing rapid fault detection to the Safety Manager.
- Fault Tolerance: When used in a redundant configuration (QMR – Quadruple Modular Redundancy), the system can continue to operate safely even if one module fails.
- Rugged Construction: Built to withstand the harsh electromagnetic and thermal conditions found in industrial control rooms and satellite instrument houses (SIH).
Important Considerations & Precautions
- Field Wiring: Ensure that the input signals are properly isolated. The 10018/E/1 expects potential-free (dry) contacts. Supplying external power to the input pins without proper coordination can damage the module.
- Rack Placement: The module must be inserted into a compatible Safety Manager or FSC chassis. Verify that the backplane pins are straight and clean before insertion.
- Heat Dissipation: While the power dissipation is low, ensuring proper airflow within the rack is essential for maintaining the long-term reliability of the safety electronic components.
- ESD Protection: Always use an anti-static wrist strap when handling the module, as the high-density semiconductor components are sensitive to electrostatic discharge.
Product Applications
The Honeywell 10018/E/1 is an essential component for the following safety-related systems:
- Emergency Shutdown (ESD): Receiving signals from manual emergency push-buttons or field-mounted pressure/level switches to trigger a plant shutdown.
- Fire & Gas (F&G): Monitoring digital signals from smoke detectors, heat detectors, or manual pull stations.
- Burner Management (BMS): Verifying the status of fuel valves and flame scanners in large furnace operations.
- Critical Process Control: Monitoring interlock signals that prevent unsafe operation of pumps, compressors, and reactors.
Shipping Port: Xiamen, China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Please make an inquiry for more models:
| Honeywell | 621-9938 30731823-001 |
| Honeywell | 82408458-002 8240846-001 |
| Honeywell | CC-PAIM01 51405046-175 |
| Honeywell | FSC10002/1/2 |
| Honeywell | FSC10014/H/F |
| Honeywell | FSC10101/2/1 |
| Honeywell | MC-TAMR03 51309218-175 |
| Honeywell | MC-TAMR04 51305907-175 |
| Honeywell | 0AH061 |
| Honeywell | 10014/F/F |
| Honeywell | 10024/I/I |
| Honeywell | 10105/2/1.10105/2/1 |
| Honeywell | 10201/2/1.10201/2/1 |
| Honeywell | 11CX12-D01 |
| Honeywell | 1TC-PPD011 |
| Honeywell | 281CX12 |
| Honeywell | 2MLR-DBSH |
| Honeywell | 330103-00-06-10-02-00 |
| Honeywell | 4000093-310 |
| Honeywell | 50MC-PAIH03 |
| Honeywell | 51201420-005 |
| Honeywell | 51204138-001 |
| Honeywell | 51204162 |
| Honeywell | 51303978 |
| Honeywell | 51303979-500 |
| Honeywell | 51304441 |
| Honeywell | 51304486-100 |
| Honeywell | 51304754-1 |
| Honeywell | 51305418-200 |
| Honeywell | 51305803-100 |