Description
Honeywell 05701-A-0301 Single-Channel Control Card
Product Overview
The Honeywell 05701-A-0301 is a 4–20 mA Single Channel Control Card designed for the Honeywell Analytics System 57 series control system. It serves as an integrated control, monitoring, and alarm unit for a single industrial gas detector channel.
The card processes incoming 4–20 mA standard analog signals from connected gas transmitters, displays real-time gas concentration data on its front panel LCD, compares readings against preset alarm thresholds, and activates visual alarms or relay contacts when limits are breached.
Technical Specifications
| Parameter | Specification Details |
|---|---|
| Manufacturer | Honeywell Analytics / Sieger |
| Part Number | 05701-A-0301 |
| Product Type | Single Channel Control Card (4–20 mA Loop Input) |
| System Compatibility | Honeywell System 57 Control Rack (3U subrack format) |
| Input Signal | 4–20 mA DC analog loop signal (fitted with 05701-A-0283 sensor drive module) |
| Supply Voltage | 18 V to 32 V DC |
| Power Consumption | ~3.25 W typical (for 4–20 mA configurations) |
| Front Panel Display | 4-part Liquid Crystal Display (LCD): |
• Analog bar graph: 25 segments
• Digital readout: 4 characters
• Message display: 4 characters
• Status icons: Power On / Card Select | | Alarm / Status LEDs | • Gas Alarms: A1, A2, A3
• System Status: Fault, Inhibit / Calibrate | | Alarm Setting Resolution | 1% of Full Scale Deflection (FSD) steps | | Electronic Drift | Less than ±2% / 6 months | | Memory / Storage | On-board non-volatile EEPROM (retains configuration setup) | | Dimensions & Weight | 170 mm (D) × 25 mm (W) × 112 mm (H) (~3U Eurocard); approx. 165 g |
Key Advantages
- High-Integrity Modular Architecture: Single-channel operation ensures that an issue with one channel will not affect adjacent channels in the System 57 rack, maximizing system reliability and uptime.
- Comprehensive Visual Interface: Features a detailed 4-part LCD providing simultaneous analog trend bar graphs, precise digital engineering unit readings, and text messages alongside high-visibility LED alarm indicators.
- Non-Volatile Configuration: Internal EEPROM stores all alarm setpoints, span/zero calibration settings, and channel parameters without risk of data loss during power outages.
- Self-Diagnostics & Fault Detection: Continuously monitors its internal circuitry, microprocessor function, line integrity, and connected sensor status to immediately alert operators to system faults.
- Flexible System Integration: Pairs seamlessly with System 57 Field Interface Cards and Relay Cards to trigger site sirens, exhaust ventilation fans, or shutdown interlocks.
Important Installation & Usage Precautions
- Input Compatibility Verification: Model
05701-A-0301is strictly designed for 4–20 mA analog inputs. (Note: Catalytic bead gas sensors require the05701-A-0302variant). - Shielding & Grounding: Sensor cabling shield/armour must be correctly connected to the system protective earth terminal to avoid false alarms caused by electromagnetic interference (EMI/RFI).
- Engineering Key Requirement: Modifying critical setup parameters (zeroing, span calibration, alarm threshold adjustment, or inhibit override) requires inserting the System 57 Engineering Card and Engineering Key into the rack.
- Hot-Swapping Guidelines: Before removing or inserting a control card into a live System 57 subrack, ensure the channel alarm outputs are set to Inhibit to prevent accidental tripping of plant safety interlocks or fire suppression devices.
- Voltage Operating Range: Maintain incoming DC power strictly between 18 V and 32 V DC to ensure stable microprocessor operation and sensor excitation voltage.
Applications
- Oil & Gas Refineries & Offshore Platforms: Continuous monitoring for hazardous toxic gas leaks (e.g., H2SH_2SH2S, COCOCO) and combustible hydrocarbons in processing bays.
- Chemical & Petrochemical Plants: Centralized gas safety detection interlocked with plant emergency shutdown (ESD) systems.
- Pharmaceutical & Industrial Manufacturing: Environmental monitoring of toxic gases, volatile organic compounds (VOCs), and oxygen depletion in production cleanrooms.
- Water & Wastewater Treatment Facilities: Gas safety monitoring for toxic gases like chlorine (Cl2Cl_2Cl2), sulfur dioxide (SO2SO_2SO2), and methane (CH4CH_4CH4) in enclosed spaces.
Shipping Port: Xiamen, China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Please make an inquiry for more models:
| Honeywell | 621-9938 30731823-001 |
| Honeywell | 82408458-002 8240846-001 |
| Honeywell | CC-PAIM01 51405046-175 |
| Honeywell | FSC10002/1/2 |
| Honeywell | FSC10014/H/F |
| Honeywell | FSC10101/2/1 |
| Honeywell | MC-TAMR03 51309218-175 |
| Honeywell | MC-TAMR04 51305907-175 |
| Honeywell | 0AH061 |
| Honeywell | 10014/F/F |
| Honeywell | 10024/I/I |
| Honeywell | 10105/2/1.10105/2/1 |
| Honeywell | 10201/2/1.10201/2/1 |
| Honeywell | 11CX12-D01 |
| Honeywell | 1TC-PPD011 |
| Honeywell | 281CX12 |
| Honeywell | 2MLR-DBSH |
| Honeywell | 330103-00-06-10-02-00 |
| Honeywell | 4000093-310 |
| Honeywell | 50MC-PAIH03 |
| Honeywell | 51201420-005 |
| Honeywell | 51204138-001 |
| Honeywell | 51204162 |
| Honeywell | 51303978 |
| Honeywell | 51303979-500 |
| Honeywell | 51304441 |
| Honeywell | 51304486-100 |
| Honeywell | 51304754-1 |
| Honeywell | 51305418-200 |
| Honeywell | 51305803-100 |