Description
Hima F7553 Safety Coupling Module
Product Dimensions:
The HIMA F7553 is a high-performance Ethernet Communication Module designed for use within the HIMatrix F-series (Programmable Logic Controllers). It serves as a bridge between the safety-related controller and external systems, allowing for seamless data exchange while maintaining functional safety standards.
### Technical Specifications (Product Parameters)
The F7553 is built to operate in demanding industrial environments where safety (SIL 3) is paramount.
| Feature | Specification |
| Model | F7553 (HIMatrix Series) |
| Function | Ethernet Communication Interface |
| Processor | Integrated high-speed communication processor |
| Interfaces | 2 x RJ45 Ethernet Ports (10/100 Mbit/s) |
| Safety Integrity Level | SIL 3 (IEC 61508) |
| Performance Level | PL e (ISO 13849) |
| Input Voltage | 24 VDC (-15% … +20%) |
| Operating Temperature | 0°C to +60°C |
| Mounting | DIN Rail / Rack Mount (depending on chassis) |
| Protocols | SafeEthernet, Modbus TCP, TCP/IP, UDP |
### Key Product Advantages
-
Certified Safety: Fully compliant with SIL 3 standards, ensuring that communication does not compromise the safety loop of the plant.
-
Dual Port Design: Features two Ethernet interfaces, often used for redundant configurations or daisy-chaining to increase system availability.
-
SafeEthernet Integration: Uses HIMA’s proprietary SafeEthernet protocol, allowing safety-related data to be transmitted over standard Ethernet infrastructure without losing safety certification.
-
Compact Form Factor: Designed to save space within the control cabinet while providing high-density connectivity.
-
High Diagnostics: Provides real-time status LEDs and software diagnostics to quickly identify network faults or hardware failures.
### Important Considerations (Precautions)
-
Network Security: While the module is safety-certified, it should be isolated from office networks using industrial firewalls to prevent cyber-attacks or broadcast storms.
-
Configuration: Must be configured using HIMA’s SILworX or ELOP II software. Ensure the firmware version of the module matches the project requirements.
-
Power Supply: Ensure a stable 24V DC power source; fluctuations outside the specified range can cause communication interruptions or module resets.
-
Grounding: Proper earthing of the Ethernet cables (shielded cables) is mandatory to prevent electromagnetic interference (EMI) from affecting data integrity.
### Product Applications
The HIMA F7553 is typically used in “Safety Instrumented Systems” (SIS) across heavy industries:
-
Emergency Shutdown (ESD) Systems: Linking distributed safety controllers across a large facility.
-
Fire and Gas (F&G) Systems: Communicating between sensors, logic solvers, and HMI stations.
-
Burner Management Systems (BMS): Safe communication between the boiler control and the central monitoring system.
-
Turbine Control: Providing high-speed data feedback for overspeed protection and control.
-
Oil & Gas Pipelines: Facilitating long-distance safety communication between remote terminal units (RTUs).
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Please make an inquiry for more models:
| HIMA | F3212A |
| HIMA | F3213A |
| HIMA | F3215A |
| HIMA | F3226(17.007) |
| HIMA | F3316 (17.031) |
| HIMA | F3328 (17.008) |
| HIMA | F3330 (17.013) |
| HIMA | F3334 |
| HIMA | F3403 (17.038) |
| HIMA | F3406a (17.049) |
| HIMA | F3410 (17.062) |
| HIMA | F3417A |
| HIMA | F3417a (17.034) |
| HIMA | F4101 (17.003) |
| HIMA | F4102 |
| HIMA | F4110 (17.058) |
| HIMA | F4111a (17.021) |
| HIMA | F4304 (17.026) |
| HIMA | F7126 |
| HIMA | F7131 |
| HIMA | F7553 (17.037) |
| HIMA | F8601 (17.036) |
| HIMA | F8620/4 |
| HIMA | F8650 (17.053) |
| HIMA | F8650E |
| HIMA | HSD8001 |
| HIMA | HSD9044 |
| HIMA | XPSMF2DO1602 |
| HIMA | Z7116/3236/C5 |
| HIMA | Z7134/3334/C5/P2 |