Description
HIMA F3105 Power Monitoring Module
Product Dimensions:
The HIMA Power Monitoring Module is a high-performance safety component designed to supervise and manage power distribution within HIMA’s safety-related automation systems (such as HIMax or HIQUAD). These modules ensure that the power supplied to the safety controllers and I/O modules remains within specified tolerances, preventing system failures or unsafe states due to power fluctuations.
1. Key Technical Parameters
While specific parameters can vary slightly depending on the exact model (e.g., for HIMax vs. HIMatrix systems), the standard specifications generally include:
| Parameter | Typical Specification |
| Input Voltage | 24 V DC (Standard range 18 V to 30 V) |
| Safety Integrity Level | Up to SIL 3 (IEC 61508) |
| Output Current Monitoring | Variable (depending on the backplane/rack configuration) |
| Response Time | < 10 ms |
| Operating Temperature | -20°C to +60°C |
| Communication Interface | Internal System Bus (SafeEthernet or proprietary backplane) |
| Redundancy Support | Support for 1-out-of-2 (1oo2) or 2-out-of-4 configurations |
2. Product Advantages
-
High Reliability: Engineered specifically for functional safety, ensuring that power faults are detected before they can compromise the safety function.
-
Diagnostic Depth: Provides real-time data on voltage levels and current consumption, allowing for predictive maintenance.
-
Seamless Integration: Fully integrated into the HIMA SILworX programming environment, making configuration and monitoring straightforward.
-
Hot-Swappable: Most HIMA power modules can be replaced during operation without interrupting the safety system (Zero Downtime).
-
Galvanic Isolation: Protects sensitive logic circuits from external electrical interference or surges.
3. Product Applications
These modules are essential in industries where “fail-safe” is the only option:
-
Oil & Gas: Emergency Shutdown Systems (ESD) and Fire & Gas (F&G) systems.
-
Chemical/Petrochemical: Burner Management Systems (BMS) and critical process control.
-
Power Generation: Turbine control and boiler protection.
-
Rail/Transport: Signaling and power distribution for safety-critical infrastructure.
4. Important Precautions (Usage Notes)
-
Correct Polarity: Always ensure 24 V DC polarity is correct; while modules have protection, reversed polarity can stress adjacent components.
-
Load Calculation: Ensure the total current draw of all I/O modules does not exceed the rated capacity of the monitoring module.
-
Environmental Limits: Do not operate the module outside the specified temperature or humidity ranges, as this can degrade the SIL rating.
-
Firmware Compatibility: When replacing a module, verify that the firmware version is compatible with the existing processor module and SILworX project version.
-
Earthing: Proper functional earthing (FE) and protective earthing (PE) are mandatory to minimize electromagnetic interference (EMI).
5. Summary of Functionality
The module acts as a “watchdog” for the system’s energy. If the voltage drops below a critical threshold (Undervoltage) or spikes too high (Overvoltage), the module triggers an alarm or initiates a safe shutdown sequence to protect the hardware and the process.
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Please make an inquiry for more models:
| HIMA | F3212A |
| HIMA | F3213A |
| HIMA | F3215A |
| HIMA | F3226(17.007) |
| HIMA | F3316 (17.031) |
| HIMA | F3328 (17.008) |
| HIMA | F3330 (17.013) |
| HIMA | F3334 |
| HIMA | F3403 (17.038) |
| HIMA | F3406a (17.049) |
| HIMA | F3410 (17.062) |
| HIMA | F3417A |
| HIMA | F3417a (17.034) |
| HIMA | F4101 (17.003) |
| HIMA | F4102 |
| HIMA | F4110 (17.058) |
| HIMA | F4111a (17.021) |
| HIMA | F4304 (17.026) |
| HIMA | F7126 |
| HIMA | F7131 |
| HIMA | F7553 (17.037) |
| HIMA | F8601 (17.036) |
| HIMA | F8620/4 |
| HIMA | F8650 (17.053) |
| HIMA | F8650E |
| HIMA | HSD8001 |
| HIMA | HSD9044 |
| HIMA | XPSMF2DO1602 |
| HIMA | Z7116/3236/C5 |
| HIMA | Z7134/3334/C5/P2 |