Description
HIMA F30 03 98 2200496 Signal Isolator
Product Dimensions:
Here is a detailed product overview of the HIMA Signal Isolator (typically part of the HIMA HIMax or HIQUAD safety systems, or specific HART-compatible isolation modules).
## Product Overview: HIMA Signal Isolator
HIMA signal isolators are high-performance safety components designed to provide galvanic isolation between field devices and the safety controller. They ensure that electrical interference, ground loops, or high-voltage transients in the field do not damage the Safety Instrumented System (SIS) or compromise the integrity of the safety loop.
## Technical Specifications (General Parameters)
While specific parameters vary by model (e.g., the HIMA HiZ series or modules for HIMax), typical specifications include:
| Parameter | Standard Value / Range |
| Input Signal | 0/4…20 mA, 0…10 V, or thermocouple/RTD |
| Output Signal | 0/4…20 mA (Active or Passive) |
| Galvanic Isolation | Up to 2.5 kV AC (Input / Output / Power) |
| Response Time | < 10 ms to 50 ms (model dependent) |
| Safety Integrity Level | SIL 3 (IEC 61508) |
| Power Supply | 24 V DC (-15% / +20%) |
| Operating Temp | -20°C to +60°C |
| Accuracy | < 0.1% of full scale |
## Key Advantages
-
Maximum Safety: Certified for use in SIL 3 loops, ensuring the highest level of functional safety.
-
Galvanic Isolation: Effectively eliminates ground loops and protects the controller from surges originating in the field.
-
HART Compatibility: Supports bi-directional communication for smart field devices, allowing for remote calibration and diagnostics.
-
High Density: Slim housing designs allow for more channels per DIN rail, saving cabinet space.
-
Fault Detection: Includes features like line fault monitoring (LFM) to detect short circuits or wire breaks in the field.
## Safety Precautions & Installation Notes
-
Wiring Integrity: Ensure that “Safe” and “Unsafe” wiring is physically separated according to local electrical codes to prevent induction.
-
Environmental Protection: Must be installed in an enclosure with at least IP54 protection if used in dusty or humid industrial environments.
-
Load Matching: Verify that the input impedance of the isolator matches the output capability of your field sensor.
-
Hot Swapping: Only perform module replacement if the specific HIMA rack/model supports “hot-plug” functionality to avoid system trips.
## Product Applications
HIMA signal isolators are used in critical infrastructure where failure is not an option:
-
Emergency Shutdown Systems (ESD): Isolating pressure and flow transmitters in oil and gas refineries.
-
Fire & Gas Systems (F&G): Connecting smoke, flame, and gas detectors to the safety logic solver.
-
Burner Management Systems (BMS): Ensuring stable signal transmission for flame scanners in high-interference environments.
-
Chemical Processing: Protecting the SIS from corrosive or volatile environments via intrinsically safe (IS) barriers.
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Please make an inquiry for more models:
| HIMA | F3212A |
| HIMA | F3213A |
| HIMA | F3215A |
| HIMA | F3226(17.007) |
| HIMA | F3316 (17.031) |
| HIMA | F3328 (17.008) |
| HIMA | F3330 (17.013) |
| HIMA | F3334 |
| HIMA | F3403 (17.038) |
| HIMA | F3406a (17.049) |
| HIMA | F3410 (17.062) |
| HIMA | F3417A |
| HIMA | F3417a (17.034) |
| HIMA | F4101 (17.003) |
| HIMA | F4102 |
| HIMA | F4110 (17.058) |
| HIMA | F4111a (17.021) |
| HIMA | F4304 (17.026) |
| HIMA | F7126 |
| HIMA | F7131 |
| HIMA | F7553 (17.037) |
| HIMA | F8601 (17.036) |
| HIMA | F8620/4 |
| HIMA | F8650 (17.053) |
| HIMA | F8650E |
| HIMA | HSD8001 |
| HIMA | HSD9044 |
| HIMA | XPSMF2DO1602 |
| HIMA | Z7116/3236/C5 |
| HIMA | Z7134/3334/C5/P2 |