Description
FACTS F2-04RTD Temperature Input Module
Product Dimensions:
The FACTS Engineering F2-04RTD is a 4-channel Resistance Temperature Detector (RTD) input module designed for use with the DirectLOGIC 205 (DL205) series PLC systems. It provides high-resolution temperature monitoring for industrial processes.
1. Product Detailed Description
The F2-04RTD module allows for the direct connection of up to four RTD sensors to a DL205 PLC base. It converts the resistance signals from the sensors into digital temperature data that the CPU can process. The module supports various RTD types (such as Pt100 and Pt1000) and provides 16-bit resolution, ensuring high precision for sensitive thermal environments.
2. Technical Specifications (Parameters)
| Feature | Specification |
| Number of Channels | 4 |
| Input Type | Pt100, Pt1000, jPT100, CU-10Ω, CU-25Ω |
| Resolution | 16-bit (0.1°C or 0.1°F) |
| Temperature Ranges | Pt100: -200°C to 850°C (-328°F to 1562°F) |
| Accuracy | ±0.1°C (Typical) |
| Update Rate | 160ms per channel (640ms for all 4) |
| Input Resistance | > 10MΩ |
| PLC System | DirectLOGIC DL205 |
| Power Consumption | 90mA (from the base 5VDC) |
3. Product Advantages
-
High Precision: The 16-bit resolution allows for detection of minute temperature changes, which is critical in chemical and food processing.
-
Flexible Scaling: Data can be displayed in Celsius, Fahrenheit, or raw digital counts.
-
Ease of Integration: It slides directly into any slot of a DL205 base and is automatically recognized by the CPU.
-
Isolation: Features 1500VAC isolation between the field side and the logic side to protect the PLC from electrical surges.
-
Cost-Effective: Eliminates the need for external temperature transmitters, saving rail space and wiring costs.
4. Important Considerations (Precautions)
-
Wiring: Use shielded twisted-pair cables for RTD connections to minimize electromagnetic interference (EMI).
-
Grounding: Ensure the shield wire is grounded at the PLC base only (single-point ground) to avoid ground loops.
-
External Power: This module usually requires a 24VDC external power supply to power the internal circuitry; ensure this is stable.
-
Sensor Leads: If using 3-wire RTDs, ensure all three wires are of the same length and gauge to maintain lead-wire compensation accuracy.
5. Typical Applications
-
HVAC Systems: Monitoring ambient air and duct temperatures in large buildings.
-
Food & Beverage: Precise temperature control in pasteurization or fermentation tanks.
-
Plastic Injection Molding: Monitoring barrel temperatures to ensure consistent melt quality.
-
Cold Storage: Managing environmental conditions in pharmaceutical or food warehouses
Shipping Port: Xiamen, China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Please make an inquiry for more models:
| BAUMULLER | BUS6-VC-0E-0036 |
| BAUMULLER | BKF12/120/400/2002 |
| BAUMULLER | GDM120N-528/0750 |
| Baumüller | BUS3-15/30-31-010 |
| BAUTZ | M406D-030-71-0 |
| BAUTZ | E642B-MGB |
| BBC | 83SR03E |
| BBC | 83SR11E |
| BBC | 88VK01E |
| BECKHOFF | AM227M-0000 |
| BECKHOFF | AM3043-1E41-0000 |
| BECKHOFF | AM3043-1E41-0000 |
| BECKHOFF | AM3043-1E41-0000 |
| BECKHOFF | CP6533-00010021 |
| Beckhoff | CP6203-0001-0020 |
| Beckhoff | C3620-0010 |
| Beckhoff | CP7201-1000-0000 |
| Beckhoff | CP6901-0001-0000 |
| BECKHOFF | CP6933-0001-0000 |
| BECKHOFF | CP7032-0001 |
| BECKHOFF | C3620-0010 |
| BEG | SAXP6P7V |
| BEHR | SEC05030017 |
| BEI | H25E-F1-SS-10 |
| BEI | H38D-1800-ABZC-8830-LED-SC-UL |
| BEI | MP2K-CCC-777-100 |
| BEIJER | E410-04822 |
| Beijer | Exeter-K70 |
| Beijer | E910TD |
| Beijer | E900TD |