Description
Emerson KJ3001X1-BK112P0556X142 Temperature Transmitter
Emerson Rosemount temperature transmitters convert raw signals from RTDs, thermocouples, and millivolt sensors into reliable industrial outputs like 4–20 mA HART, FOUNDATION Fieldbus, or WirelessHART. Here is a complete breakdown of the lineup, specs, advantages, precautions, and core models.
Emerson Electric
The Emerson Rosemount 848T Temperature Transmitter consolidates up to eight independent temperature inputs into a single field-hardened housing to cut wiring costs in high-density zones.
Technical Specifications
- Supported Inputs: Universal sensor inputs including 2-, 3-, and 4-wire RTDs (Pt100, Pt1000, Ni, Cu), Thermocouples (Types B, E, J, K, N, R, S, T), millivolts (mV), and ohms.
Emerson Electric
- Output Protocols: 2-wire 4–20 mA / HART (Revisions 5 & 7), FOUNDATION Fieldbus, PROFIBUS PA, and IEC 62591 WirelessHART.
Emerson Electric
- Power Supply: 12.0 to 42.4 V DC loop power (wired HART models) or Intrinsically Safe Lithium-thionyl chloride SmartPower module (wireless models).
Emerson Electric
- Galvanic Isolation: Input-to-output isolation tested to 500 V AC rms (707 V DC) at 50/60 Hz.
Emerson Electric
- Ambient Operating Temp: -50 °C to +85 °C (-58 °F to +185 °F), with optional cold-temp ratings down to -60 °C.
- Ingress & Enclosure Ratings: NEMA Type 4X, IP66 / IP68 (field-mount low-copper aluminum or 316 stainless steel housings).
Emerson Electric+ 1
- Safety & Hazardous Approvals: IEC 61508 SIL 2 / SIL 3 certified (3144P, 3144S, 644), plus ATEX, IECEx, FM, and CSA explosion-proof and intrinsic safety approvals.
Emerson Electric+ 1
Key Advantages
- Transmitter-Sensor Matching: Uses Callendar-Van Dusen (CVD) constants to match the transmitter to a specific RTD curve, cutting total measurement error by up to 75%.
Emerson Electric+ 1
- Hot Backup Redundancy: Dual-sensor models automatically switch to a secondary sensor if the primary element fails, preventing process shutdowns.
Emerson Electric
- Non-Intrusive X-well Technology: Calculates internal pipe fluid temperature from a surface clamp sensor, eliminating thermowells, pipe penetrations, and leak points.
Emerson Electric+ 1
- Predictive Diagnostics: Tracks sensor drift alerts, thermocouple loop resistance degradation, and min/max temperature extremes before sudden failure occurs.
Emerson Electric
- Long-Term Stability: Five-year stability ratings on premium models extend calibration intervals and cut field maintenance trips.
Emerson Electric
Important Installation & Usage Precautions
- Loop Load Resistance: Wired HART communicators require at least 250 ohms of loop resistance and a minimum 17.75 V DC power supply at the terminals.
Emerson Electric
- Sensor Wiring & Shielding: Keep sensor lead wires short, twisted, and shielded away from high-voltage AC power lines to prevent electromagnetic noise.
- Cold Junction Compensation (CJC): When wiring thermocouples directly to the transmitter, use matching extension wire all the way to the terminal block so internal CJC stays accurate.
- Hazardous Area Compliance: Verify that enclosure thread types (1/2-14 NPT vs. M20×1.5) and cable glands match your site’s Ex d (Flameproof) or Ex ia (Intrinsically Safe) zone rules.
Emerson Electric
- X-well Piping Limits: Only use X-well surface measurement on metal pipes with known thermal conductivity and process temperatures within -50 °C to +300 °C.
Emerson Electric+ 1
Primary Applications
- Oil & Gas / Refining: Reactor bed profiling, custody transfer metering, and flare or pipeline temperature monitoring.
Emerson Electric
- Chemical & Petrochemical: Exothermic reactor safety loops (SIL 2/3), distillation columns, and storage tank inventory.
Emerson Electric
- Power Generation: Steam turbine bearings, boiler feedwater lines, and heat recovery steam generators (HRSG).
- Pharmaceutical & Food/Beverage: Clean-in-Place (CIP) / Steam-in-Place (SIP) skids and hygienic sanitary thermowell assemblies.
Emerson Electric
Shipping Port: Xiamen, China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Please make an inquiry for more models:
| Emerson | 12P0678X022 |
| Emerson | 12P0678X032 |
| Emerson | 12P0681X072 |
| Emerson | 12P0683X082 |
| Emerson | 12P1064X072 |
| Emerson | 12P1064X08R |
| Emerson | 12P1064X122 |
| Emerson | 12P1442X042 |
| Emerson | 12P1509X052 |
| Emerson | 12P1731X082 |
| Emerson | 12P1732X042 |
| Emerson | 12P1732X062 |
| Emerson | 12P2186X012 |
| Emerson | 12P2471X042 |
| Emerson | 12P2506X062 |
| Emerson | 12P2536X042 |
| Emerson | 12P3162X162 |
| Emerson | 12P3935X032 |
| Emerson | 12P4986X |
| Emerson | 13A0054G04 |
| Emerson | 13A0066G01 |
| Emerson | 13A0066G02 |
| Emerson | 13A0066G04 |
| Emerson | 13A0068G02 |
| Emerson | 13A0069G01 |
| Emerson | 13A0070H17 |
| Emerson | 13A0072G01 |
| Emerson | 13A0073G08 |
| Emerson | 13A0076G01 |
| Emerson | 13D0092G01 |