EMERSON KJ2003X1-BA2 Controller
Product Dimensions:
The Emerson KJ2003X1-BA2 is a high-performance Local Bus Extender (Right Hand) module designed for the DeltaV™ Distributed Control System (DCS). It is a critical component for expanding the physical reach of the DeltaV controller’s I/O bus.
1. Product Detailed Description
The KJ2003X1-BA2 acts as a bridge for the DeltaV local bus. In a standard DeltaV setup, the I/O carriers are attached directly to the controller. However, when the number of I/O modules exceeds the space of a single row or cabinet, this extender module is used.
-
Function: It extends the communication and power bus from one power supply/controller carrier to the next set of I/O carriers.
-
Design: It is specifically the Right Hand (RH) version, typically used at the end of a row to “send” the bus signal via a cable to the next row’s “Left Hand” extender.
2. Technical Parameters
| Feature | Specification |
| Model Number | KJ2003X1-BA2 |
| Series | DeltaV S-Series / M-Series |
| Input Power | 12 VDC via local bus |
| Current Consumption | 0.5 A (Maximum) |
| Operating Temperature | -40°C to 70°C (-40°F to 158°F) |
| Storage Temperature | -40°C to 85°C (-40°F to 185°F) |
| Relative Humidity | 5% to 95% (Non-condensing) |
| Isolation | None (Direct bus connection) |
3. Key Product Advantages
-
Scalability: Allows the DeltaV system to grow by adding more I/O modules across multiple rows without needing additional controllers.
-
Hot-Swappable: Like most DeltaV components, it can be replaced while the system is powered (though bus communication to downstream modules will be interrupted).
-
Industrial Durability: Built to withstand harsh environments with wide temperature ranges and G3 conformal coating options for corrosion resistance.
-
Plug-and-Play: Integrated seamlessly into the DeltaV Explorer software for easy diagnostics and configuration.
4. Important Considerations & Precautions
-
Cable Length Limits: Ensure that the total length of the extension cables does not exceed the maximum bus length specified by Emerson (typically 10 meters or 33 feet total for the entire bus).
-
Orientation Matters: The BA2 is a Right-Hand extender. It must be paired correctly with a Left-Hand extender (KJ2003X1-BB1) on the receiving row.
-
Power Budget: While the extender carries the data bus, you must ensure the downstream carriers have their own power supplies if the voltage drop across the extension is too high.
-
ESD Protection: Always use a grounding wrist strap when handling the module to prevent Electrostatic Discharge damage to the internal circuitry.
5. Product Applications
The KJ2003X1-BA2 is found in large-scale industrial automation environments where high I/O density is required, such as:
-
Oil & Gas: Refineries and offshore platforms.
-
Chemical Plants: For managing complex batch processing.
-
Pharmaceuticals: Maintaining precise control over environmental and chemical variables.
-
Power Generation: Managing plant-wide logic and monitoring.
Shipping Port: Xiamen, China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Please make an inquiry for more models:
| Emerson | 12P0678X022 |
| Emerson | 12P0678X032 |
| Emerson | 12P0681X072 |
| Emerson | 12P0683X082 |
| Emerson | 12P1064X072 |
| Emerson | 12P1064X08R |
| Emerson | 12P1064X122 |
| Emerson | 12P1442X042 |
| Emerson | 12P1509X052 |
| Emerson | 12P1731X082 |
| Emerson | 12P1732X042 |
| Emerson | 12P1732X062 |
| Emerson | 12P2186X012 |
| Emerson | 12P2471X042 |
| Emerson | 12P2506X062 |
| Emerson | 12P2536X042 |
| Emerson | 12P3162X162 |
| Emerson | 12P3935X032 |
| Emerson | 12P4986X |
| Emerson | 13A0054G04 |
| Emerson | 13A0066G01 |
| Emerson | 13A0066G02 |
| Emerson | 13A0066G04 |
| Emerson | 13A0068G02 |
| Emerson | 13A0069G01 |
| Emerson | 13A0070H17 |
| Emerson | 13A0072G01 |
| Emerson | 13A0073G08 |
| Emerson | 13A0076G01 |
| Emerson | 13D0092G01 |