Description
Emerson 1C31147G01 Electromagnetic Flowmeter
Emerson’s electromagnetic flowmeters (marketed under the Rosemount™ brand, including the 8700M Series, 8750W, and 9000 Series) measure volumetric flow of conductive liquids using Faraday’s Law of Electromagnetic Induction. Below is a complete breakdown alongside core models from the Rosemount lineup.
Product Detailed Description
- Working Principle: Based on Faraday’s Law, magnetic coils generate a controlled field across an insulated flow tube. As conductive liquid passes through, electrodes detect an induced voltage directly proportional to fluid velocity.
- System Architecture: Consists of a Flow Sensor (flanged 8705/8750W/9205, wafer 8711, or hygienic 8721) paired with a Transmitter (8732E integral/field-mount, 8712E wall-mount, or 9732).Emerson Electric
- Wetted Materials: Offers chemical-resistant liners (PTFE, PFA, ETFE, Polyurethane, Neoprene) and electrodes (316L SST, Alloy C-276, Tantalum, Platinum-Iridium, Titanium).Emerson Electric
Technical Specifications
- Line Sizes: 0.5 in. (15 mm) up to 48 in. (1,200 mm) depending on sensor seriesEmerson Electric
- Reference Accuracy: ±0.25% of rate standard; up to ±0.15% of rate optionalEmerson Electric
- Velocity Range: 0.04 to 39 ft/s (0.01 to 12 m/s), bidirectional
- Minimum Fluid Conductivity: ≥ 5 µS/cm (5 micromhos/cm)
- Power Supply: 90–250 VAC (50/60 Hz) or 12–42 VDC
- Output & Protocols: 4–20 mA with HART®, FOUNDATION™ Fieldbus, Modbus® RS-485, EtherNet/IP™, and scalable pulse outputEmerson Electric
- Ingress Protection: IP66 / NEMA 4X for transmitters; up to IP68 (submersible) for welded sensorsEmerson Electric
- Ambient Temperature: -40 °C to +60 °C (-40 °F to +140 °F)
Key Advantages
- Zero Pressure Drop & No Moving Parts: The unobstructed bore prevents clogging, eliminates mechanical wear, and avoids pumping energy losses.Keco Engineered Controls
- Smart Meter Verification (SMV): Checks sensor coil, electrode, and electronics calibration health in-line without halting flow or removing the meter.
- Superior Noise Rejection: High-signal coil drive and selectable frequencies maintain stable readings in heavy slurries, pulp fibers, and entrained-air flows.Emerson Electric+ 1
- Through-the-Glass Setup: Optical switches (8732E) or wireless Bluetooth® (9732) allow safe commissioning in hazardous areas without opening covers.Emerson Electric
Important Precautions & Usage Notes
- Conductivity Requirement: Cannot measure non-conductive fluids such as hydrocarbons, oils, gases, steam, or ultra-pure deionized water (< 5 µS/cm).
- Full-Pipe Condition: The flow tube must remain 100% full of liquid at all times; install in vertical upward-flow lines or low horizontal sections to avoid air pockets.
- Straight-Run Piping: Follow upstream/downstream straight-pipe rules (typically 5D upstream / 2D downstream) away from pumps, elbows, and throttling valves.
- Proper Grounding: Always install grounding rings or grounding electrodes when mounting in plastic, lined, or non-conductive pipes to prevent signal drift.
- Liner Compatibility: Never apply vacuum or temperatures above the selected liner rating (e.g., PTFE vs. Polyurethane), as high vacuum can collapse soft liners.Emerson Electric
Typical Applications
- Water & Wastewater (Rosemount 8750W): Municipal water distribution, raw sewage, lift stations, and sludge monitoring.Emerson Electric
- Chemical & Petrochemical (Rosemount 8705 / 9000 Series): Corrosive acids, caustics, and aggressive process reagents.Emerson Electric+ 1
- Mining, Pulp & Paper (Rosemount MS / 8782): Abrasive mining slurries, sand, and high-consistency paper stock.Emerson Electric+ 1
- Food, Beverage & Pharma (Rosemount 8721): Sanitary CIP/SIP processes, dairy, brewing, and sterile batching.Emerson Electric+ 1
- Data Centers & HVAC (Rosemount 8795): Chilled-water thermal cooling loops and hydronic energy tracking.Emerson Electric
Recommendation
- Pick the Rosemount 8705 + 8732E for demanding chemical, industrial, or hazardous-area processes needing an all-welded sensor and explosion-proof transmitter.Emerson Electric
- Pick the Rosemount 8750W for municipal water, wastewater, and general utility lines where IP68 durability and lifecycle value matter most.Emerson Electric+ 1
Shipping Port: Xiamen, China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Please make an inquiry for more models:
| Emerson | 12P0678X022 |
| Emerson | 12P0678X032 |
| Emerson | 12P0681X072 |
| Emerson | 12P0683X082 |
| Emerson | 12P1064X072 |
| Emerson | 12P1064X08R |
| Emerson | 12P1064X122 |
| Emerson | 12P1442X042 |
| Emerson | 12P1509X052 |
| Emerson | 12P1731X082 |
| Emerson | 12P1732X042 |
| Emerson | 12P1732X062 |
| Emerson | 12P2186X012 |
| Emerson | 12P2471X042 |
| Emerson | 12P2506X062 |
| Emerson | 12P2536X042 |
| Emerson | 12P3162X162 |
| Emerson | 12P3935X032 |
| Emerson | 12P4986X |
| Emerson | 13A0054G04 |
| Emerson | 13A0066G01 |
| Emerson | 13A0066G02 |
| Emerson | 13A0066G04 |
| Emerson | 13A0068G02 |
| Emerson | 13A0069G01 |
| Emerson | 13A0070H17 |
| Emerson | 13A0072G01 |
| Emerson | 13A0073G08 |
| Emerson | 13A0076G01 |
| Emerson | 13D0092G01 |