Description
Emerson 12P1064X122kj2002x1-ba1 Vortex Flowmeter
Emerson offers its industrial vortex flowmeters under the Rosemount™ 8800 and Rosemount™ 8600 series, designed for measuring liquids, gases, and steam.
Product Overview
- Operating Principle: Uses the Von Kármán vortex street effect. As fluid flows past a non-streamlined bluff body (shedder bar), it creates alternating swirling vortices at a frequency directly proportional to flow velocity.
- Sensor Architecture: A mass-balanced piezoelectric sensor behind the shedder bar detects pressure pulses from the vortices without contacting the process fluid.
- Body Styles: Available in Flanged, Wafer (flangeless), Reducer (built-in reduced bore for low flows), Weld-End, and Threaded-End configurations.
Technical Parameters
- Volumetric Accuracy:
- Liquids: ±0.65% of flow rate
- Gases & Steam: ±1.0% of flow rate
- MultiVariable Mass Flow (Steam): ±1.2% to ±2.5% depending on pressure and compensation mode
- Turndown Ratio: Up to 38:1 (Rosemount 8800) or 30:1 (Rosemount 8600)
- Process Temperature Range:
- Rosemount 8800: -200 °C to +427 °C (-330 °F to +800 °F)
- Rosemount 8600: -50 °C to +250 °C (-58 °F to +482 °F)
- Line Sizes:
- Rosemount 8800: DN15 to DN350 (1/2 in. to 14 in., depending on style)
- Rosemount 8600: DN25 to DN200 (1 in. to 8 in.)
- Pressure Ratings: ASME Class 150 to 1500, DIN PN10 to PN160, JIS 10K to 40K
- Wetted Materials: 316/316L & CF3M stainless steel, Nickel Alloy C-22/CW2M, carbon steel (A105/WCB, LF2/LCC), and Duplex stainless steel
- Output Signals: 4–20 mA with HART 5 or 7, scalable pulse output (0–10,000 Hz), FOUNDATION Fieldbus, or Modbus RS-485
- Power Supply: 10.8 to 42 VDC (16.8 VDC minimum required for HART communication)
Key Advantages
- Zero Leak Points & Non-Clog Body: The all-cast, gasket-free Rosemount 8800 body removes internal ports and impulse lines that typically clog or leak.
- Online Sensor Replacement: Both flow and temperature sensors sit isolated from the process fluid, allowing technicians to swap them without shutting down or depressurizing the pipe.
- High Vibration Immunity: Mass-balanced sensors paired with Adaptive Digital Signal Processing (ADSP) filter out pipe vibration and low-flow noise.
- Built-In Diagnostics & Verification: An internal signal generator lets technicians verify electronics without removing the meter, while Smart Fluid Diagnostics detect liquid-to-gas phase changes.
- Lower Installed Cost with Reducer & MultiVariable Models: Integral reducer bodies eliminate field-welded pipe reducers, and built-in temperature sensors remove the need for separate thermowells.
Installation & Usage Precautions
- Straight-Pipe Run Requirements: Leave sufficient straight unobstructed pipe upstream (typically 10–35 pipe diameters depending on elbows or valves) and downstream (5 pipe diameters) to avoid swirl and flow profile distortion.
- Gasket Protrusion: Ensure flange gaskets align with the pipe’s inner diameter—gaskets extending into the bore disturb vortex shedding and cause measurement errors.
- Minimum Reynolds Number: Vortex meters need turbulent flow (typically Re > 10,000 for linear accuracy). Avoid high-viscosity fluids or ultra-low flow velocities where vortices stop shedding cleanly.
- Control Valve Placement: Always install control valves downstream of the vortex flowmeter so valve throttling or flashing does not disrupt incoming flow.
- Two-Phase & Dirty Slurry Limits: Designed for clean, single-phase liquids, gases, and steam. Heavy solids, fibrous slurries, or wet gas slugs can coat the shedder bar or trigger false counts.
- High-Temperature Electronics Orientation: When measuring hot steam above 200 °C, mount the transmitter housing to the side or bottom of a horizontal pipe (or use remote-mount electronics) so rising heat doesn’t overheat the circuit board.
Applications
- Steam & Boiler Systems: Saturated and superheated steam mass flow monitoring, boiler efficiency tracking, and plant energy allocation.
- Chemical & Petrochemical Processing: Corrosive solvents, hydrocarbon gases, nitrogen blanketing, and clean-in-place (CIP) blowdown detection.
- Power Generation & Utilities: Compressed air, chilled/cooling water, natural gas headers, and condensate return lines.
- Safety Instrumented Systems (SIS): High-integrity flow interlocks (up to SIL 3) using the Dual or Quad Rosemount 8800 configurations.
Verdict
Choose the Rosemount 8800 Series for critical process lines, extreme temperatures (-200 °C to +427 °C), or steam mass-flow compensation. Choose the Rosemount 8600 Series when you need a simpler meter for clean utility water, air, or general steam headers.
Shipping Port: Xiamen, China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Please make an inquiry for more models:
| Emerson | 12P0678X022 |
| Emerson | 12P0678X032 |
| Emerson | 12P0681X072 |
| Emerson | 12P0683X082 |
| Emerson | 12P1064X072 |
| Emerson | 12P1064X08R |
| Emerson | 12P1064X122 |
| Emerson | 12P1442X042 |
| Emerson | 12P1509X052 |
| Emerson | 12P1731X082 |
| Emerson | 12P1732X042 |
| Emerson | 12P1732X062 |
| Emerson | 12P2186X012 |
| Emerson | 12P2471X042 |
| Emerson | 12P2506X062 |
| Emerson | 12P2536X042 |
| Emerson | 12P3162X162 |
| Emerson | 12P3935X032 |
| Emerson | 12P4986X |
| Emerson | 13A0054G04 |
| Emerson | 13A0066G01 |
| Emerson | 13A0066G02 |
| Emerson | 13A0066G04 |
| Emerson | 13A0068G02 |
| Emerson | 13A0069G01 |
| Emerson | 13A0070H17 |
| Emerson | 13A0072G01 |
| Emerson | 13A0073G08 |
| Emerson | 13A0076G01 |
| Emerson | 13D0092G01 |