Description
BENDER VME421H-D-1 Voltage Monitoring Relay
Product Dimensions:
The Bender VME421H-D-1 is a high-precision digital voltage monitoring relay designed for single-phase and three-phase AC/DC systems. It is part of the VME421 series, specifically engineered to detect undervoltage, overvoltage, and window voltage conditions to protect sensitive electrical equipment.
Product Detailed Description
The VME421H-D-1 monitors the voltage between two thresholds (Min/Max). It features a built-in digital display for real-time monitoring and parameter configuration. The “H” in the model name typically indicates a higher functional range or specific auxiliary power requirements, and the “D-1” version is optimized for DIN rail mounting with specific delay timing capabilities.
Technical Parameters
| Parameter | Specification |
| Monitored Network | 1-Phase AC/DC or 3-Phase AC systems |
| Nominal Voltage (U_n) | AC 0…300 V / DC 0…300 V |
| Supply Voltage (U_s) | AC/DC 100…240 V (Wide range) |
| Frequency Range | DC / 15…460 Hz |
| Measuring Channels | 3-phase (L1, L2, L3, N) |
| Response Value Overvoltage | 10 V…300 V (Adjustable) |
| Response Value Undervoltage | 10 V…300 V (Adjustable) |
| Output Contacts | 2 Changeover contacts (SPDT) |
| Time Delay (t_{on} / t_{off}) | 0…100 seconds (Adjustable) |
| Display | Multi-functional LCD with backlight |
Product Advantages
- High Versatility: A single unit can monitor both AC and DC systems, as well as 3-phase networks without a neutral conductor.
- True RMS Measurement: Provides accurate voltage readings even in harmonically distorted networks caused by VFDs or electronic loads.
- Precision Timing: Adjustable response and release delays prevent nuisance tripping caused by momentary voltage fluctuations or motor starting.
- Self-Monitoring: The device includes a permanent self-test feature; if an internal fault is detected, the alarm relays will signal a system error.
- Password Protection: Settings can be locked to prevent unauthorized personnel from changing safety thresholds.
Important Considerations (Precautions)
- Auxiliary Power: Ensure the auxiliary supply voltage (U_s) matches the specifications (100–240V). Operating outside this range may damage the internal electronics.
- Wiring Topology: When monitoring 3-phase systems without a neutral, ensure the parameters are correctly set in the menu to “3AC” to avoid false phase-failure alarms.
- Contact Rating: Do not exceed the maximum switching capacity of the output relays (typically 5A/250VAC). Use intermediate contactors for high-power loads.
- Environment: Avoid installing the unit in areas with high electromagnetic interference (EMI) without proper shielding, as it may affect the measurement accuracy.
Product Applications
The VME421H-D-1 is used where voltage stability is critical for operational safety:
- Control Cabinets: Protecting PLCs, HMIs, and sensitive electronics from brownouts or overvoltage spikes.
- Renewable Energy: Monitoring the output voltage of inverters in solar or wind power systems before grid connection.
- Mechanical Engineering: Protecting 3-phase motors from overheating due to phase imbalance or undervoltage.
- Infrastructure: Monitoring emergency power supplies (UPS) and standby generators in hospitals or data centers.
Shipping Port: Xiamen, China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Please make an inquiry for more models:
| BASLER | BE1-25A |
| BASLER | exA1390-19m |
| BASLER | 125-15-B2C1V |
| BASLER | BE1-11-F5A1M0H2N000 |
| BASLER | BE1-87T-E1E-A1L-NON2F |
| BASLER | BE1-87T-E1F-A1J-N0N0F |
| BASLER | BE1-87T-E4EA1KD0N5F |
| BASLER | SR8A-2B01B3A |
| BATTENFELD | PDVS-102/1 |
| BATTENFELD | PDVS-102/1 |
| BAUER | BG06-31/D05LA4 |
| BAUMER | FHDK14P5101/S35A |
| BAUMER | OADM20I6572/S14F |
| BAUMER ELECTRIC | FLDK110C1002/S24 |
| BAUMULLER | BUR622-16-2 |
| BAUMULLER | GDM120N-528/0750 |
| BAUMULLER | BKF12/70/400-2001 |
| BAUMULLER | BUS3-15/30-30-004 |
| BAUMULLER | BUG20-120-30-B-000 |
| BAUMULLER | BUG2-60-31-0-209 |
| BAUMULLER | BUM62-075/100-54-000 |
| BAUMULLER | BUM62-075/97.5-54-0-000 |
| BAUMULLER | BUM62F-75/975-54-M-041 |
| BAUMULLER | BUM62T-100-130-54-0-006 |
| BAUMULLER | BUS20-160/270-31-022 |
| BAUMULLER | BUS20-160/270-31-023 |
| BAUMULLER | BUS21-15/30-30-004 |
| BAUMULLER | BUS21-15/30-31-020 |
| BAUMULLER | BUS21-30/60-31-031 |
| BAUMULLER | DSG45-M-A |