Bender VMD421H-D-3 Voltage Monitoring Relay
Product Dimensions:
The Bender VMD421H-D-3 is a multi-functional digital voltage monitoring relay designed for three-phase AC systems. It is part of the LINETRAXX® series and is widely used for protecting electrical installations against voltage and frequency fluctuations.
Below is the detailed product information in English.
1. Product Overview
The VMD421H-D-3 monitors undervoltage, overvoltage, and frequency in 3(N)AC systems. It also includes functions for asymmetry (unbalance), phase failure, and phase sequence monitoring. The device is self-powered from the monitored system and features an integrated energy backup to maintain operation during brief power interruptions.
2. Technical Parameters
| Feature | Specification |
| Nominal System Voltage ($U_n$) | 3(N)AC 70…500 V (L-L) / 70…288 V (L-N) |
| Frequency Range ($f_n$) | 15…460 Hz |
| Measuring Range | AC 0…500 V (L-L) / 0…288 V (L-N) |
| Response Values | Undervoltage: 70…500 V; Overvoltage: 70…500 V |
| Output Contacts | 2 changeover contacts (K1, K2), independently configurable |
| Time Delays | Start-up delay ($t$): 0…300 s; Response delay ($t_{on}$): 0…300 s |
| Hysteresis | 1…40% (Voltage) / 0.1…2 Hz (Frequency) |
| Connection Type | Screw terminals (D-3 variant) |
| Enclosure Width | 36 mm (2 modules) |
3. Key Advantages
-
Multifunctional Monitoring: Combines voltage, frequency, phase sequence, and asymmetry monitoring in a single compact device.
-
Self-Powered: No external auxiliary supply voltage is required, simplifying the installation and reducing wiring.
-
Digital Display: The multi-functional LC display provides real-time monitoring of system values and easy parameterization.
-
Energy Backup: Integrated energy storage ensures the device can signal a power failure and maintain the alarm state for up to 2.5 seconds.
-
Preset Function: Includes an automatic setting function for basic parameters based on the detected nominal system voltage ($U_n$).
4. Product Applications
-
Industrial Protection: Monitoring of voltage-sensitive machines and electrical installations.
-
Emergency Systems: Monitoring of stand-by and emergency supply systems (e.g., generators).
-
Motor Protection: Protecting three-phase motors against phase failure, phase reversal, and asymmetrical loads.
-
Transformer Monitoring: Detection of asymmetrical loads to protect distribution transformers.
-
Portable Loads: Monitoring supply voltage for mobile or portable equipment.
5. Important Considerations & Precautions
-
Installation Safety: Installation must be performed by a qualified electrician. For systems $> 400$ V, strict adherence to local electrical safety standards is mandatory.
-
Short-Circuit Protection: It is highly recommended to use 5 A fuses at the sensing inputs (L1, L2, L3, N) for short-circuit protection.
-
Neutral (N) Connection: The Neutral connection is only necessary if you intend to monitor Phase-to-Neutral ($L-N$) voltages.
-
Configuration Lock: Use the password protection feature to prevent unauthorized changes to the setpoints and delay times.
-
Latching Mode: If “Fault Memory” (Latching) is enabled, the device must be manually reset using the “R” button after a fault has been cleared.
Shipping Port: Xiamen, China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Please make an inquiry for more models:
| BASLER | BE1-25A |
| BASLER | exA1390-19m |
| BASLER | 125-15-B2C1V |
| BASLER | BE1-11-F5A1M0H2N000 |
| BASLER | BE1-87T-E1E-A1L-NON2F |
| BASLER | BE1-87T-E1F-A1J-N0N0F |
| BASLER | BE1-87T-E4EA1KD0N5F |
| BASLER | SR8A-2B01B3A |
| BATTENFELD | PDVS-102/1 |
| BATTENFELD | PDVS-102/1 |
| BAUER | BG06-31/D05LA4 |
| BAUMER | FHDK14P5101/S35A |
| BAUMER | OADM20I6572/S14F |
| BAUMER ELECTRIC | FLDK110C1002/S24 |
| BAUMULLER | BUR622-16-2 |
| BAUMULLER | GDM120N-528/0750 |
| BAUMULLER | BKF12/70/400-2001 |
| BAUMULLER | BUS3-15/30-30-004 |
| BAUMULLER | BUG20-120-30-B-000 |
| BAUMULLER | BUG2-60-31-0-209 |
| BAUMULLER | BUM62-075/100-54-000 |
| BAUMULLER | BUM62-075/97.5-54-0-000 |
| BAUMULLER | BUM62F-75/975-54-M-041 |
| BAUMULLER | BUM62T-100-130-54-0-006 |
| BAUMULLER | BUS20-160/270-31-022 |
| BAUMULLER | BUS20-160/270-31-023 |
| BAUMULLER | BUS21-15/30-30-004 |
| BAUMULLER | BUS21-15/30-31-020 |
| BAUMULLER | BUS21-30/60-31-031 |
| BAUMULLER | DSG45-M-A |