Description
BENDER IR425-D4-2 Insulation Monitor
Product Dimensions:
The BENDER IR425-D4-2 is a sophisticated Insulation Monitoring Device (IMD) designed for unearthed AC, AC/DC, and DC systems (IT systems). It is a critical safety component used to monitor the insulation resistance between the system conductors and the earth (ground) in real-time, providing an early warning before a full ground fault occurs.
Product Detailed Description
The IR425-D4-2 is part of the ISOMETER® family. In an IT (Isolated Terra) system, the first insulation fault does not trip a circuit breaker, allowing the process to continue. This device monitors that first fault, measuring the insulation resistance (R_F) and comparing it against two independently adjustable response values (Alarm 1 and Alarm 2). It features a digital display for local monitoring and relay outputs for remote signaling.
Technical Parameters
| Feature | Specification |
| Model Number | IR425-D4-2 |
| Monitored System | AC, AC/DC, or DC (0 to 300 V) |
| Supply Voltage (U_s) | AC 100 to 240 V / DC 100 to 240 V |
| Response Value 1 (R_{an1}) | 1 kΩ to 200 kΩ (Pre-alarm) |
| Response Value 2 (R_{an2}) | 1 kΩ to 200 kΩ (Main alarm) |
| Measuring Principle | AMP (Adaptive Measuring Pulse) |
| Display | Digital LC display (shows R_F and parameters) |
| Output Contacts | 2 Changeover contacts (Form C) |
| Enclosure Width | 36 mm (2 modules wide) |
| Mounting | DIN rail (IEC 60715) |
Product Advantages
- AMP Technology: Uses Bender’s patented Adaptive Measuring Pulse technology, which allows it to accurately monitor systems with high leakage capacitances and DC components without false tripping.
- Preventive Maintenance: By identifying deteriorating insulation before a short circuit occurs, it prevents unexpected downtime and equipment damage.
- Compact Design: The 36mm width saves significant space in control cabinets and distribution boards.
- Self-Monitoring: Continuously monitors the connection to the earth and the monitored system; if a wire break is detected, the device signals a fault.
- Password Protection: Prevents unauthorized changes to the safety settings and alarm thresholds.
Important Considerations (Precautions)
- IT Systems Only: This device is strictly for unearthed (IT) systems. Do not use it in TN (grounded neutral) or TT systems, as it will signal a continuous fault.
- Only One IMD: In any galvanically connected IT system, only one insulation monitoring device may be connected. Multiple IMDs will interfere with each other’s measuring pulses.
- Voltage Limits: Ensure the system voltage does not exceed 300V AC/DC. For higher voltages, an external coupling device (like the AGH series) may be required.
- Wiring Check: Ensure the connection to terminal E (Earth) and KE (Functional Earth) are separate for the wire-break monitoring feature to function correctly.
Product Applications
- Industrial Automation: Protecting sensitive control circuits and motor drives where a sudden power cut would ruin a production batch.
- Medical Facilities: Used in “Group 2” medical locations (operating theaters, ICUs) to ensure life-support equipment remains powered during a first fault.
- Mobile Power: Monitoring generators on ships, mobile cranes, or emergency power vehicles.
- Renewable Energy: Monitoring the insulation of DC strings in small to medium-sized photovoltaic (PV) systems.
Shipping Port: Xiamen, China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Please make an inquiry for more models:
| BASLER | BE1-25A |
| BASLER | exA1390-19m |
| BASLER | 125-15-B2C1V |
| BASLER | BE1-11-F5A1M0H2N000 |
| BASLER | BE1-87T-E1E-A1L-NON2F |
| BASLER | BE1-87T-E1F-A1J-N0N0F |
| BASLER | BE1-87T-E4EA1KD0N5F |
| BASLER | SR8A-2B01B3A |
| BATTENFELD | PDVS-102/1 |
| BATTENFELD | PDVS-102/1 |
| BAUER | BG06-31/D05LA4 |
| BAUMER | FHDK14P5101/S35A |
| BAUMER | OADM20I6572/S14F |
| BAUMER ELECTRIC | FLDK110C1002/S24 |
| BAUMULLER | BUR622-16-2 |
| BAUMULLER | GDM120N-528/0750 |
| BAUMULLER | BKF12/70/400-2001 |
| BAUMULLER | BUS3-15/30-30-004 |
| BAUMULLER | BUG20-120-30-B-000 |
| BAUMULLER | BUG2-60-31-0-209 |
| BAUMULLER | BUM62-075/100-54-000 |
| BAUMULLER | BUM62-075/97.5-54-0-000 |
| BAUMULLER | BUM62F-75/975-54-M-041 |
| BAUMULLER | BUM62T-100-130-54-0-006 |
| BAUMULLER | BUS20-160/270-31-022 |
| BAUMULLER | BUS20-160/270-31-023 |
| BAUMULLER | BUS21-15/30-30-004 |
| BAUMULLER | BUS21-15/30-31-020 |
| BAUMULLER | BUS21-30/60-31-031 |
| BAUMULLER | DSG45-M-A |