Description
Bender CTAC120 Measuring Current Transformer
Product Dimensions:
The Bender CTAC120 is a highly sensitive, window-type measuring current transformer (CT) from the LINETRAXX® CTAC series. It is specifically designed to work in conjunction with Bender’s residual current monitors (RCM/RCMS series) and insulation fault location systems (EDS series).
Product Detailed Description
The CTAC120 is an essential component for monitoring residual currents in earthed (TN/TT) systems or locating insulation faults in unearthed (IT) systems. It features a large 120 mm inner diameter, allowing it to accommodate large cable bundles or busbars. By encircling all current-carrying conductors (including the neutral, but excluding the protective earth), the CTAC120 detects the vector sum of currents; any non-zero result indicates a leakage or fault current.
Technical Parameters
| Parameter | Specification |
| Model | CTAC120 (Art. No. B98110019) |
| Inside Diameter | 120 mm |
| Rated Transformation Ratio (K_r) | 600 / 1 |
| Rated Voltage (U_n) | 800 V |
| Frequency Range | 15 Hz to 100 kHz |
| Rated Continuous Thermal Current (I_{cth}) | 125 A |
| Rated Short-time Thermal Current (I_{th}) | 2.4 kA / 1 s |
| Rated Dynamic Current (I_{dyn}) | 50 kA / 50 ms |
| Weight | Approx. 1140 g |
| Operating Temperature | -25°C to +70°C |
| Connection Type | Screw terminals (0.2…2.5 mm²) |
Product Advantages
- High Sensitivity: Capable of detecting very low residual currents, starting from as low as 100 mA (depending on the connected evaluator), enabling early fault detection before damage occurs.
- Large Aperture: The 120 mm window is ideal for heavy-duty industrial applications where large-diameter cables or multiple conductors are used.
- Wide Frequency Response: With a range from 15 Hz up to 100 kHz, it is suitable for modern power systems with high-frequency harmonics or variable speed drives.
- Seamless Integration: Fully compatible with the Bender ecosystem, providing plug-and-play functionality with RCMS460/490 monitors and EDS440 fault locators.
Important Considerations (Precautions)
- Conductor Routing: All active conductors (L1, L2, L3, and N) must pass through the CT window. The protective earth (PE) conductor must never pass through the CT.
- Shielding: Do not route shielded cables through the CTAC120. If a shielded cable must pass through, the shield must be pulled back and grounded outside the CT window.
- Centering: For maximum accuracy, conductors should be centered within the transformer and not bent sharply immediately before or after the CT.
- Testing: Regular “bump tests” via the connected RCM device are recommended to ensure the entire measurement loop is operational.
Product Applications
- Data Centers & Hospitals: Continuous monitoring of leakage currents to prevent unplanned downtime in critical facilities.
- Industrial Plants: Early detection of insulation degradation in large motors, heaters, or distribution panels.
- IT Systems (Unearthed): Working as a “locating CT” in Insulation Fault Location Systems (EDS) to pinpoint the exact branch where a fault has occurred.
- Fire Prevention: Monitoring for residual currents in buildings to reduce the risk of electrical fires caused by insulation failure.
Shipping Port: Xiamen, China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Please make an inquiry for more models:
| BASLER | BE1-25A |
| BASLER | exA1390-19m |
| BASLER | 125-15-B2C1V |
| BASLER | BE1-11-F5A1M0H2N000 |
| BASLER | BE1-87T-E1E-A1L-NON2F |
| BASLER | BE1-87T-E1F-A1J-N0N0F |
| BASLER | BE1-87T-E4EA1KD0N5F |
| BASLER | SR8A-2B01B3A |
| BATTENFELD | PDVS-102/1 |
| BATTENFELD | PDVS-102/1 |
| BAUER | BG06-31/D05LA4 |
| BAUMER | FHDK14P5101/S35A |
| BAUMER | OADM20I6572/S14F |
| BAUMER ELECTRIC | FLDK110C1002/S24 |
| BAUMULLER | BUR622-16-2 |
| BAUMULLER | GDM120N-528/0750 |
| BAUMULLER | BKF12/70/400-2001 |
| BAUMULLER | BUS3-15/30-30-004 |
| BAUMULLER | BUG20-120-30-B-000 |
| BAUMULLER | BUG2-60-31-0-209 |
| BAUMULLER | BUM62-075/100-54-000 |
| BAUMULLER | BUM62-075/97.5-54-0-000 |
| BAUMULLER | BUM62F-75/975-54-M-041 |
| BAUMULLER | BUM62T-100-130-54-0-006 |
| BAUMULLER | BUS20-160/270-31-022 |
| BAUMULLER | BUS20-160/270-31-023 |
| BAUMULLER | BUS21-15/30-30-004 |
| BAUMULLER | BUS21-15/30-31-020 |
| BAUMULLER | BUS21-30/60-31-031 |
| BAUMULLER | DSG45-M-A |