AutomationDirect F2-02DA-2 PLC Analog Output Module
Product Overview
The AutomationDirect F2-02DA-2 is a 2-channel analog current output module designed for the DL205 DirectLOGIC PLC series. It converts digital values from the CPU into precise 4–20 mA current signals to drive field control devices such as control valves, variable frequency drives (VFDs), proportional valves, and panel meters.
This module installs directly into any available I/O slot of a DL205 base (such as D2-06B-1 or D2-09B-1) and operates under the control of DL205 CPUs (e.g., D2-240, D2-250-1, D2-260, or DL205 Ethernet/Devicenet base controllers).
Technical Specifications
| Parameter | Specification Details |
| Product Model | F2-02DA-2 |
| PLC Compatibility | DL205 Series (DirectLOGIC) |
| Number of Channels | 2 isolated current output channels |
| Output Range | 4 to 20 mA |
| Resolution | 12-bit (1 in 4096 counts, 0 to 4095 range) |
| Output Type | Current sink/source (loop powered by external supply) |
| External Loop Power Supply | 24 VDC ± 10% (max 80 mA) |
| Maximum Load Impedance | 0 to 1250 Ω @ 24 VDC |
| Accuracy vs. Temperature | ±50 ppm/°C maximum drift |
| Maximum Absolute Error | ±0.1% of full scale @ 25 °C; ±0.3% over full temp range |
| Conversion Time | 100 µs maximum (full scale step response) |
| Base Power Consumption | 60 mA max @ 5 VDC from base backplane |
| Terminal Type | Removable 10-point terminal block |
Key Advantages
- High Accuracy & Stability: Delivers ±0.1% accuracy at room temperature with minimal thermal drift for precise analog signal control.
- Fast Response Time: Features a 100 µs conversion update rate, making it suitable for dynamic control loops such as pressure regulation and speed control.
- Easy Field Maintenance: Equipped with a removable terminal block that allows module replacement without rewiring field connections.
- Compact Integration: Fits into the compact DL205 form factor, saving space inside control cabinets.
- Proven Reliability: Long-standing industrial design tailored for rugged manufacturing and processing environments.
Important Usage & Installation Precautions
- External Power Required: The module requires a 24 VDC external power supply connected to the terminal block to power the 4–20 mA current loops. It will not output current using backplane power alone.
- Load Loop Impedance: Ensure total circuit resistance (wiring + field device input impedance) does not exceed 1250 Ω at 24 VDC to maintain linear loop current.
- Shielding & Grounding: Always use twisted-pair shielded cable for 4–20 mA signals. Ground the shield at the PLC chassis ground only to avoid ground loops.
- Module Placement: Avoid placing the analog module directly adjacent to high-voltage AC I/O modules or switching power supplies to reduce electromagnetic interference (EMI).
- Power-Down Wiring: Always disconnect power to the base and the external 24 VDC loop supply before inserting or removing the module or terminal block.
Applications
- Variable Frequency Drive (VFD) Speed Control: Provides a 4–20 mA reference signal to control motor speeds on pumps, fans, and conveyors.
- Proportional Valve Control: Modulates flow, pressure, or position on hydraulic and pneumatic systems.
- Process Heating & Temperature Control: Interfaces with SCR power controllers or modulating gas valves for industrial ovens and furnaces.
- Process Instrumentation: Sends analog variables to remote chart recorders, panel indicators, or secondary signal isolators.
Shipping Port: Xiamen, China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Please make an inquiry for more models:
| Automation ABM-507B-2-S-CE-S293 | ||
| AUTOMATION EZ-T10C-F | ||
| AUTONET HFAI-08 | ||
| AUTONET HFDI-16 | ||
| AVAL DATA AVME-115A | ||
| AVAYA P5507FT-C | ||
| AVG 100G-1S1R0 | ||
| AVG 100G-3C1R0 | ||
| AVG 100G-5A1R0 | ||
| AVG 100G-5A1R0M | ||
| AVG 100GUT15T3R0 | ||
| AVG 100G-UT15T3R1 | ||
| AVG UTP10TC0A00 | ||
| AXIOM P1150/586T | ||
| AZBIL FL7M-7J6HD-CN03 | ||
| Ball WA564588-500 | ||
| Ball WA564585-500 | ||
| Ball WA564464-500 | ||
| Ball WA564456-500 | ||
| Balluff BIS-C-810-0003-X | ||
| Balzers PM-P02-372 | ||
| BANNER USDKTE4824C5YP2 | ||
| BANNER MSKA4424C1 | ||
| BANNER P4GRK2308SRRE | ||
| BARBER 80NA-00001-002-0-00 | ||
| BARDEN 122HDL | ||
| BARDEN 126HDBTL | ||
| BARKSDALE 9045ROAC3-MC-H | ||
| barksdale BPS34GVM0010B | ||
| BASLER BE1-25A | ||
| BASLER exA1390-19m | ||
| BASLER 125-15-B2C1V | ||
| BASLER BE1-11-F5A1M0H2N000 | ||
| BASLER BE1-87T-E1E-A1L-NON2F | ||
| BASLER BE1-87T-E1F-A1J-N0N0F |