Description

ABB TMAX T5N630 Molded case circuit breakers

The ABB SACE Tmax T5N 630 is a high-performance Moulded Case Circuit Breaker (MCCB) designed for reliable protection and isolation in low-voltage electrical distribution systems. It is part of ABB’s robust Tmax T series.

📋 Product Details

  • Product Name: Moulded Case Circuit Breaker (MCCB)

  • Series: SACE Tmax T

  • Sub-type/Frame Size: T5N

  • Version/Mounting: Fixed (F) with Front Terminals (F)

  • Poles: Typically 3-pole (for three-phase systems), though 4-pole versions may be available.

  • Release Type (Example): Often equipped with a Solid-State Release like the PR221DS-LS/I which offers:

    • Long-Time delay protection (Overload Protection)

    • Short-Time delay protection (Short-circuit protection with delay)

    • Instantaneous protection (Immediate high-current short-circuit protection)

⚙️ Product Parameters (Technical Specifications)

Parameter Specification
Rated Current ($I_n$) 630 A
Number of Poles 3
Rated Operational Voltage ($U_e$) Max 690 V AC (Also rated for DC)
Rated Insulation Voltage ($U_i$) 1000 V
Rated Impulse Withstand Voltage ($U_{imp}$) 8 kV
Rated Ultimate Short-Circuit Breaking Capacity ($I_{cu}$) 36 kA at 380/400/415 V AC (Varies with voltage, e.g., 20 kA at 690 V AC)
Rated Service Short-Circuit Breaking Capacity ($I_{cs}$) Typically equal to $I_{cu}$ for the ‘N’ performance level (e.g., 36 kA at 400 V AC)
Mechanical Durability Approx. 20,000 cycles
Electrical Durability Approx. 5,000 cycles
Dimensions (Typical) Width: 140 mm, Height: 205 mm, Depth: 103.5 mm
Standards IEC 60947-2

Note: Specifications can vary based on the exact model code (e.g., trip unit and performance level).

✨ Product Advantages

  • High Breaking Capacity: The ‘N’ version offers a high ultimate short-circuit breaking capacity ($I_{cu}$) of up to 36 kA at 400V, ensuring safety under severe fault conditions.

  • Advanced Protection: The electronic trip units (like PR221DS) provide precise, adjustable, and reliable protection (L, S, I) for better selectivity and system coordination compared to purely thermal-magnetic units.

  • Compact Design: Despite its high current rating (630A), the Tmax T5 frame maintains a relatively small footprint, optimizing panel space.

  • Versatility: Suitable for use in AC and DC applications and offers a wide range of accessories for enhanced functionality (e.g., auxiliary contacts, shunt trips, motor operators).

  • Ease of Maintenance: The fixed mounting and front terminal connection design allow for straightforward installation, wiring, and maintenance access.

⚠️ Important Notes (Precautions)

  • Installation: Installation and commissioning must be carried out by qualified personnel in accordance with the manufacturer’s instructions, local wiring regulations, and safety standards (e.g., IEC/EN standards).

  • Coordination: For optimal performance and selectivity in a distribution network, the trip unit settings (L, S, I) must be properly coordinated with the protective devices upstream and downstream.

  • Accessories: Only use genuine ABB accessories designed for the Tmax T5 frame to ensure proper fit and performance.

  • Torque: Always ensure all terminal connections are tightened to the manufacturer’s specified torque values to prevent loose connections, overheating, and potential failure.

  • Inspection: Regular visual inspection and functional testing of the MCCB and its trip unit are recommended to confirm its operational readiness.

🎯 Product Applications

The ABB Tmax T5N 630 MCCB is ideal for demanding power distribution and protection applications in various sectors:

  • Industrial Plants: Used as a main breaker or sub-main breaker in main distribution boards (MDBs) and motor control centers (MCCs) to protect large loads and feeders.

  • Commercial Buildings: Employed in main and floor distribution panels for high-current loads, HVAC systems, and lighting circuits.

  • Infrastructure: Used in utilities, data centers, hospitals, and transportation systems where continuous and reliable power protection is critical.

  • Generator Protection: Suitable for use as a breaker for connecting large generators to the network.

Shipping Port: Xiamen, China

Payment: Bank of Chicago, Bank of Singapore

Express cooperation: fedex, DHL, UPS and your express account

Service: Professional Sales provides 24 hours /7 days online service

Please make an inquiry for more models:

ABB TU810v1
ABB DSQC400
ABB S1N125
ABB 3HAC028940-003
ABB 3HAB5760-1/06
ABB TB521-ETH-OTD
ABB PM591-ETH-OTD
ABB 3HAC025338-006
ABB ACS350-03E-01A9
ABB ACS510-01-157A-4
ABB AI845
ABB TU8383BSE008572R1
ABB AO810V23BSE038415R1
ABB RDNA-01
ABB 3HAC028954-004/03
ABB ACS355-03E-08A8-4
ABB TB84PH2000112
ABB TB82PH1010112
ABB TB567J1308T20
ABB PFEA111-65
ABB NAIO-03
ABB 3HNE00313-1
ABB CI626
ABB ACS550-01-06A9-4
ABB A95-30-22
ABB 3HAC2493-1
ABB CI854A
ABB HDL36150
ABB GJR5251300R0161
ABB DSQC378B