ABB TMAX T5N630 Molded case circuit breakers
The ABB SACE Tmax T5N 630 is a high-performance Moulded Case Circuit Breaker (MCCB) designed for reliable protection and isolation in low-voltage electrical distribution systems. It is part of ABB’s robust Tmax T series.
📋 Product Details
-
Product Name: Moulded Case Circuit Breaker (MCCB)
-
Series: SACE Tmax T
-
Sub-type/Frame Size: T5N
-
Version/Mounting: Fixed (F) with Front Terminals (F)
-
Poles: Typically 3-pole (for three-phase systems), though 4-pole versions may be available.
-
Release Type (Example): Often equipped with a Solid-State Release like the PR221DS-LS/I which offers:
-
Long-Time delay protection (Overload Protection)
-
Short-Time delay protection (Short-circuit protection with delay)
-
Instantaneous protection (Immediate high-current short-circuit protection)
-
⚙️ Product Parameters (Technical Specifications)
| Parameter | Specification |
| Rated Current ($I_n$) | 630 A |
| Number of Poles | 3 |
| Rated Operational Voltage ($U_e$) | Max 690 V AC (Also rated for DC) |
| Rated Insulation Voltage ($U_i$) | 1000 V |
| Rated Impulse Withstand Voltage ($U_{imp}$) | 8 kV |
| Rated Ultimate Short-Circuit Breaking Capacity ($I_{cu}$) | 36 kA at 380/400/415 V AC (Varies with voltage, e.g., 20 kA at 690 V AC) |
| Rated Service Short-Circuit Breaking Capacity ($I_{cs}$) | Typically equal to $I_{cu}$ for the ‘N’ performance level (e.g., 36 kA at 400 V AC) |
| Mechanical Durability | Approx. 20,000 cycles |
| Electrical Durability | Approx. 5,000 cycles |
| Dimensions (Typical) | Width: 140 mm, Height: 205 mm, Depth: 103.5 mm |
| Standards | IEC 60947-2 |
Note: Specifications can vary based on the exact model code (e.g., trip unit and performance level).
✨ Product Advantages
-
High Breaking Capacity: The ‘N’ version offers a high ultimate short-circuit breaking capacity ($I_{cu}$) of up to 36 kA at 400V, ensuring safety under severe fault conditions.
-
Advanced Protection: The electronic trip units (like PR221DS) provide precise, adjustable, and reliable protection (L, S, I) for better selectivity and system coordination compared to purely thermal-magnetic units.
-
Compact Design: Despite its high current rating (630A), the Tmax T5 frame maintains a relatively small footprint, optimizing panel space.
-
Versatility: Suitable for use in AC and DC applications and offers a wide range of accessories for enhanced functionality (e.g., auxiliary contacts, shunt trips, motor operators).
-
Ease of Maintenance: The fixed mounting and front terminal connection design allow for straightforward installation, wiring, and maintenance access.
⚠️ Important Notes (Precautions)
-
Installation: Installation and commissioning must be carried out by qualified personnel in accordance with the manufacturer’s instructions, local wiring regulations, and safety standards (e.g., IEC/EN standards).
-
Coordination: For optimal performance and selectivity in a distribution network, the trip unit settings (L, S, I) must be properly coordinated with the protective devices upstream and downstream.
-
Accessories: Only use genuine ABB accessories designed for the Tmax T5 frame to ensure proper fit and performance.
-
Torque: Always ensure all terminal connections are tightened to the manufacturer’s specified torque values to prevent loose connections, overheating, and potential failure.
-
Inspection: Regular visual inspection and functional testing of the MCCB and its trip unit are recommended to confirm its operational readiness.
🎯 Product Applications
The ABB Tmax T5N 630 MCCB is ideal for demanding power distribution and protection applications in various sectors:
-
Industrial Plants: Used as a main breaker or sub-main breaker in main distribution boards (MDBs) and motor control centers (MCCs) to protect large loads and feeders.
-
Commercial Buildings: Employed in main and floor distribution panels for high-current loads, HVAC systems, and lighting circuits.
-
Infrastructure: Used in utilities, data centers, hospitals, and transportation systems where continuous and reliable power protection is critical.
-
Generator Protection: Suitable for use as a breaker for connecting large generators to the network.
Shipping Port: Xiamen, China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Please make an inquiry for more models:
| ABB | TU810v1 |
| ABB | DSQC400 |
| ABB | S1N125 |
| ABB | 3HAC028940-003 |
| ABB | 3HAB5760-1/06 |
| ABB | TB521-ETH-OTD |
| ABB | PM591-ETH-OTD |
| ABB | 3HAC025338-006 |
| ABB | ACS350-03E-01A9 |
| ABB | ACS510-01-157A-4 |
| ABB | AI845 |
| ABB | TU8383BSE008572R1 |
| ABB | AO810V23BSE038415R1 |
| ABB | RDNA-01 |
| ABB | 3HAC028954-004/03 |
| ABB | ACS355-03E-08A8-4 |
| ABB | TB84PH2000112 |
| ABB | TB82PH1010112 |
| ABB | TB567J1308T20 |
| ABB | PFEA111-65 |
| ABB | NAIO-03 |
| ABB | 3HNE00313-1 |
| ABB | CI626 |
| ABB | ACS550-01-06A9-4 |
| ABB | A95-30-22 |
| ABB | 3HAC2493-1 |
| ABB | CI854A |
| ABB | HDL36150 |
| ABB | GJR5251300R0161 |
| ABB | DSQC378B |