The Bently Nevada Output Module is a key component in Bently Nevada’s machinery protection and condition monitoring systems. It serves as the interface between the monitoring system and external devices such as control systems, alarm panels, annunciators, or distributed control systems (DCS). The module converts internal digital or analog signals into standardized outputs that can trigger alarms, initiate shutdowns, or provide real-time data to external systems for process control and safety management.
Product Specifications
Parameter | Description |
---|---|
Module Types | Relay Output, Analog Output (4–20 mA, 0–10 V), Digital Output, etc. |
Output Channels | Typically 4, 8, or 16 channels per module (varies by model) |
Signal Types | Dry contact relays, current loops, voltage outputs, TTL/CMOS logic levels |
Update Rate | Typically <10 ms per channel (real-time response) |
Isolation | Channel-to-channel and channel-to-backplane optical or galvanic isolation |
Power Requirements | Typically 24 VDC, with power consumption dependent on channel load |
Operating Temperature | –30°C to +70°C (–22°F to +158°F) |
Communication Interface | Compatible with Bently Nevada 3500/3300/1700 series monitoring systems |
Certifications | UL, CE, ATEX, CSA, IECEx (varies by model and configuration) |
Product Advantages
- High Reliability: Designed for mission-critical applications in harsh industrial environments.
- Flexible Output Options: Supports a wide range of output types to interface with diverse control systems.
- Fast Response Time: Real-time signal conversion ensures timely alarm and shutdown actions.
- Modular Design: Hot-swappable in many systems, minimizing downtime during maintenance.
- Robust Isolation: Prevents ground loops and cross-talk between channels for signal integrity.
- Wide Compatibility: Integrates seamlessly with Bently Nevada monitoring systems and third-party DCS/PLC systems.
- Diagnostic Capabilities: Many modules include self-diagnostics and health status reporting.
Precautions
- Wiring Compliance: Follow manufacturer wiring diagrams and grounding practices to avoid signal interference or damage.
- Load Limitations: Do not exceed the rated voltage/current per channel to prevent relay contact welding or module failure.
- Environmental Protection: Ensure the module is installed in a suitable enclosure with appropriate IP rating for the operating environment.
- Firmware Compatibility: Verify that the module firmware is compatible with the host monitoring system.
- Maintenance Access: Allow adequate space for module replacement and ensure power is disconnected during servicing.
- Configuration Accuracy: Incorrect configuration may lead to false alarms or failure to trigger when required.
- Surge Protection: Use appropriate surge protection devices if the module is installed in environments prone to voltage spikes.
Product Applications
- Turbine Control Systems: Outputs used to trigger emergency shutdowns or alarm notifications in steam/gas turbines.
- Compressor and Pump Stations: Relay outputs to control local annunciators or interface with plant DCS.
- Power Generation: Integration with plant-wide control systems for generator and exciter monitoring.
- Oil & Gas Platforms: Alarm and trip outputs for critical machinery protection on offshore and onshore facilities.
- Chemical and Process Plants: Analog outputs for continuous process variable feedback to control systems.
- Mining and Heavy Industries: Used in harsh environments for machinery protection and automated process control.
- Marine and Offshore Vessels: Outputs for alarm panels and automated shutdown systems in propulsion and auxiliary machinery.
Shipping Port: Xiamen, China
Payment: Bank of Chicago, Bank of Singapore
Express cooperation: fedex, DHL, UPS and your express account
Service: Professional Sales provides 24 hours /7 days online service
Please make an inquiry for more models:
BENTLY NEVADA | 3300XL 8MM |
BENTLY NEVADA | 330101-00-18-10-02-05 |
BENTLY NEVADA | 330101-00-28-10-02-05 |
BENTLY NEVADA | 330103-00-03-10-02-05 |
BENTLY NEVADA | 330103-00-04-10-02-05 |
BENTLY NEVADA | 330103-00-05-05-02-05 |
BENTLY NEVADA | 330103-00-05-10-02-05 |
BENTLY NEVADA | 330103-00-14-10-01-00 |
BENTLY NEVADA | 330103-00-18-05-02-05 |
BENTLY NEVADA | 330103-05-10-10-02-05 |
BENTLY NEVADA | 330103-10-14-10-02-05 |
BENTLY NEVADA | 330104-00-04-10-02-05 |
BENTLY NEVADA | 330104-00-06-10-11-00 |
BENTLY NEVADA | 330104-00-11-10-02-05 |
BENTLY NEVADA | 330104-05-13-10-02-00 |
BENTLY NEVADA | 330104-13-20-10-02-00 |
BENTLY NEVADA | 330104-15-23-10-02-00 |
BENTLY NEVADA | 330104-19-25-10-11-05 |
BENTLY NEVADA | 330105-02-12-90-02-05 |
BENTLY NEVADA | 330130-040-02-05 |
BENTLY NEVADA | 330130-045-02-05 |
BENTLY NEVADA | 330173-00-18-10-02-05 |
BENTLY NEVADA | 330703-000-040-10-11-00 |
BENTLY NEVADA | 330730-080-02-00 |
BENTLY NEVADA | 330780-91-00 |
BENTLY NEVADA | 330930-040-01-00 |
BENTLY NEVADA | 33104-00-10-10-02-05 |
BENTLY NEVADA | 3500/05 3500/05-01-02-00-00-01 |
BENTLY NEVADA | 3500/15 127610-01 |
BENTLY NEVADA | 3500/22M 138607-01 |