140G-K-ELP Allen‑Bradley Residual current device

Brand: Allen‑Bradley

Model number:140G-K-ELP

Colour:new                                    Warranty: 12 months

Lead Time:3-day working day   Country of origin: USA

Price: Please contact us         Product weight:0.25kg

Category: SKU: 140G-K-ELP Brand:

Description

140G-K-ELP Allen‑Bradley Residual current device

Product Dimensions:

Product Detailed Description

The Allen-Bradley 140G-K-ELP is an Earth Leakage Protector (ELP) accessory designed for integration with Bulletin 140G-K frame Molded Case Circuit Breakers (MCCBs). It provides residual current protection to detect and trip on ground faults or leakage currents, enhancing electrical safety in low-voltage power distribution systems. This accessory is a plug-in module that installs on the side of the 140G-K frame breaker, compatible with thermal-magnetic or electronic trip units. It is part of Rockwell Automation’s 140G series, which offers global compliance (UL, CSA, IEC, CCC) for reliable overcurrent and fault protection. The ELP module includes a test button for functional verification and is engineered for use in industrial environments where ground fault protection is critical to prevent equipment damage or hazards.

Product Parameters

The 140G-K-ELP is tailored for the K-frame (rated up to 400 A). Key specifications include:

Parameter Details
Frame Compatibility 140G-K (3-pole or 4-pole configurations)
Rated Current (In) Up to 400 A (aligned with K-frame breaker)
Sensitivity (Residual Current) Typically 30 mA to 300 mA (adjustable; exact value depends on configuration, e.g., Type A or AC residual current)
Voltage Rating 480Y/277 V AC, 415 V AC (system-dependent)
Breaking Capacity (I_cu) 50–200 kA @ 415 V AC; 35–150 kA @ 480 V AC (inherits from host K-frame breaker)
Trip Type Instantaneous residual current release (integrated with LSI/LSIG trip units)
Mounting Side plug-in installation; torque: 7.1 lb-in (0.8 Nm) for connections
Dimensions (Approximate) Adds ~2.91″ H x 1.59″ W x 0.82″ D (74 mm x 40.5 mm x 21 mm) to breaker; total with escutcheon: up to 5.45″ H for 4-pole
Operating Temperature -25°C to +70°C (-13°F to +158°F)
Certifications UL 489, CSA C22.2 No. 5, IEC/EN 60947-2, CCC
Weight ~0.5–1 lb (0.23–0.45 kg, module only)
Test Function Manual test button (‘T’) for verifying trip on simulated leakage

Note: Full electrical parameters are coordinated with the host 140G-K breaker; consult Rockwell Automation for exact sensitivity settings.

Product Advantages

  • Enhanced Safety: Detects low-level ground faults (as low as 30 mA) to prevent electric shock, fire risks, and equipment downtime, complying with global standards like IEC 60364.
  • Seamless Integration: Plug-and-play design with 140G-K frames minimizes installation time and supports modular upgrades without replacing the entire breaker.
  • High Reliability: Proven interrupting ratings up to 200 kA ensure robust performance in demanding environments; selective coordination isolates faults without cascading trips.
  • Cost-Effective Protection: Combines earth leakage with overcurrent protection in one unit, reducing panel space and wiring complexity compared to separate RCDs.
  • Global Versatility: Multi-standard certifications (UL/CSA/IEC) allow use in North American, European, and Asian markets, with multilingual installation guides.
  • Easy Maintenance: Built-in test button and visual indicators simplify periodic verification, extending system lifespan.

Precautions and Notices

  • Safety First: To prevent electrical shock or injury, always disconnect power sources before installing, servicing, or testing the ELP. Use appropriate PPE and follow lockout/tagout procedures.
  • Installation Guidelines: Install in a suitable enclosure free from contaminants (dust, moisture). Torque connections precisely (e.g., 1.2 Nm for plugs) to avoid loose contacts. For through-door applications, ensure door thickness ≤25 mm (0.98″) if using escutcheons.
  • Testing Protocol: Press the test button (‘T’) only with the unit powered and system de-energized downstream; verify breaker opens fully. Perform monthly tests per site safety protocols—failure to trip indicates malfunction.
  • Environmental Limits: Avoid exposure to corrosive atmospheres or temperatures outside -25°C to +70°C. Do not exceed rated fault currents; selectivity may fail if prospective short-circuit > I_s (selectivity limit, e.g., 5–85 kA depending on setup).
  • Compatibility Check: Ensure host breaker is 140G-K frame with compatible trip unit (LSI/LSIG). Not for reverse-feed unless specified. Refer to publication 140G-IN (installation instructions) for wiring diagrams.
  • Warranty Note: Improper handling voids warranty; consult Rockwell Automation for repairs.

Product Applications

The 140G-K-ELP is ideal for industrial and commercial low-voltage (up to 480 V) systems requiring ground fault protection alongside overcurrent safeguarding:

  • Power Distribution Panels: Main or branch circuit protection in factories, data centers, and hospitals to isolate leakage faults quickly.
  • Motor Control Centers (MCCs): Safeguards motors and drives from ground faults in manufacturing lines, HVAC systems, and pumping stations.
  • Critical Infrastructure: Used in emergency lighting, fire alarms, and standby generators where personnel safety and uptime are paramount.
  • Commercial Buildings: Elevators, lighting circuits, and EV charging stations to meet NEC/NFPA 70E requirements for GFCI-like protection.
  • Renewable Energy: Solar inverters and wind turbine controls, ensuring fault isolation in grounded systems.
  • Marine/Offshore: Harsh environments with high humidity, leveraging IP-rated enclosures for reliable operation.

For detailed configurations or simulations, use Rockwell’s Circuit Breaker Simulator Tool. Always verify with site-specific engineering for optimal selectivity.

Shipping Port: Xiamen, China

Payment: Bank of Chicago, Bank of Singapore

Express cooperation: fedex, DHL, UPS and your express account

Service: Professional Sales provides 24 hours /7 days online service

Please make an inquiry for more models:

AB 1746-OB16
AB 1746-OB16E
AB 1746-OB32
AB 1746-OB32E
AB 1746-OB8
AB 1746-OBP16
AB 1746-OG16
AB 1746-OV16
AB 1746-OV32
AB 1746-OW16
AB 1746-OW16/C
AB 1746-OW16/C/D
AB 1746-OW4
AB 1746-OW8
AB 1746-OX8
AB 1746-P1
AB 1746-P2
AB 1746-P2/C
AB 1746-P3
AB 1746-P4
AB 1746-P5
AB 1746-P6
AB 1746-P7
AB 1746SC-NI8U
AB 1746SC-OAP8I
AB 1747-ACN15
AB 1747-ACNR15
AB 1747-ACNR15/A
AB 1747-ASB
AB 1747-ASB/A
AB 1747-ASB1747-L511
AB 1747-BA
AB 1747-BSN
AB 1747-BSN1771-IFE
AB 1747-CP3/A